m+Medelevator.RU
← Поиск публикаций
The Israel Medical Association journal : IMAJ · 2016

Transapical Transcatheter Valve-in-Valve Implantation for Failed Mitral Valve Bioprosthesis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nachum Eyal R, Raanani Ehud, Segev Amit, Guetta Victor, Hai Ilan, Shinfeld Amihai, Fefer Paul, Ashraf Hamdan, Barabash Israel, Shalabi Amjad, Spiegelstein Dan

Аннотация

UNLABELLED: Background: The rate of mitral bioprosthesis implantation in clinical practice is increasing. Transcatheter valve-in- valve implantation has been described for high risk patients requiring redo valve surgery.

OBJECTIVES: To report our experience with transapical valve-in-valve implantation for failed mitral bioprosthesis.

METHODS: Since 2010, 10 patients have undergone transapical valve-in-valve implantation for failed bioprosthesis in our center. Aortic valve-in-valve implantation was performed in one of them and mitral valve-in-valve implantation in nine. Mean age was 82 ± 4 years and 6 were female (67%). Mean time from original mitral valve (MV) replacement to valve-in-valve procedure was 10.5 ± 3.7 years. Follow-up was completed by all patients with a mean duration of 13 ± 12 months.

RESULTS: Preoperatively, all patients presented with significant mitral regurgitation, two with mitral stenosis due to structural valve failure. All nine patients underwent successful transapical valve-in-valve implantation with an Edwards Sapien balloon expandable valve. There was no in-hospital mortality. Mean and median hospital duration was 15 ± 18 and 7 days respectively. Valve implantation was successful in all patients and there were no major complications, except for major femoral access bleeding in one patient. At last follow-up, all patients were alive and in NYHA functional class I or II. Echocardiography follow-up demonstrated that mitral regurgitation was absent or trivial in seven patients and mild in two. At follow-up, peak and mean gradients changed from 26 ± 4 and 8 ± 2 at baseline to 16.7 ± 3 and 7.3 ± 1.5, respectively.

CONCLUSIONS: Transcatheter transapical mitral valve-in-valve implantation for failed bioprosthesis is feasible in selected high risk patients. Our early experience with this strategy is encouraging. Larger randomized trials with long-term clinical and echocardiographic follow-up are recommended.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты