Inci Sinan, Nar Gökay, Erol Mustafa Kemal, Demirelli Selami, Duman Hakan, Serdar Serkan, Erol Fatih
Аннотация
AIM: The aim of this study was to evaluate the effects of percutaneous mitral balloon valvuloplasty (PMBV) on short- and intermediate-term aortic stiffness in patients with mitral stenosis.
MATERIALS AND METHODS: This prospective study included 56 patients with critical mitral stenosis in normal sinus rhythm (68% female; mean age: 42 ± 11 years) and 37 healthy controls. Aortic stiffness was measured using transthoracic echocardiography before PMBV, and 24-48 hours and 1 year post procedure.
RESULTS: Aortic strain and distensibility were significantly higher in the patients with mitral stenosis, both after PMBV and 1 year post procedure, whereas the aortic stiffness index (ASI) was significantly lower. There was also a significant decrease in mitral mean gradient (MMG) and systolic pulmonary artery pressure (sPAP) after PMBV, based on echocardiography and catheterization. Mitral valve area (MVA) significantly increased after PMBV. There was a significant correlation between change in ∆MVA and ∆MMG and aortic elastic properties. There was a significantly negative correlation between the ∆MVA and ∆∆ aortic stiffness (r = -0.62, P < 0.001), and a significantly positive correlation between ∆MMG and ∆ASI (r = 0.60, P < 0.001).
CONCLUSION: Mitral valve stenosis was associated with impaired aortic stiffness and following PMBV, aortic stiffness decreased during both the acute period and the intermediate period.
MATERIALS AND METHODS: This prospective study included 56 patients with critical mitral stenosis in normal sinus rhythm (68% female; mean age: 42 ± 11 years) and 37 healthy controls. Aortic stiffness was measured using transthoracic echocardiography before PMBV, and 24-48 hours and 1 year post procedure.
RESULTS: Aortic strain and distensibility were significantly higher in the patients with mitral stenosis, both after PMBV and 1 year post procedure, whereas the aortic stiffness index (ASI) was significantly lower. There was also a significant decrease in mitral mean gradient (MMG) and systolic pulmonary artery pressure (sPAP) after PMBV, based on echocardiography and catheterization. Mitral valve area (MVA) significantly increased after PMBV. There was a significant correlation between change in ∆MVA and ∆MMG and aortic elastic properties. There was a significantly negative correlation between the ∆MVA and ∆∆ aortic stiffness (r = -0.62, P < 0.001), and a significantly positive correlation between ∆MMG and ∆ASI (r = 0.60, P < 0.001).