MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jocs.12293

Медицинская библиотека · Journal of cardiac surgery · 2014

Minimally invasive mitral valve surgery utilizing heart port technology.

Vallabhajosyula Prashanth, Wallen Tyler J, Solometo Lauren P, Fox Jeanne, Vernick William J, Hargrove W Clark

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine operative outcomes of right mini-thoracotomy mitral valve surgery utilizing port access technology in first-time and reoperative cardiac surgery patients.

METHODS

From 2002 to 2011, 881 patients underwent minimally invasive mitral valve surgery. Of these, 154 patients had previous cardiac operations via sternotomy (Group 1), of which 18 (12%) had two previous operations. Seven hundred and twenty-seven patients had no previous cardiac operations (Group 2).

RESULTS

Patient demographics were similar in both groups. In Group 1, 76 (49%) patients had previous coronary artery bypass grafting, 13 (8%) had previous aortic valve surgery, and 57 (37%) had previous mitral valve surgery. Preoperative echo findings for Groups 1 and 2 included severe mitral regurgitation (MR) (88%, n = 135; 94%, n = 687), mitral stenosis (MS) (4%, n = 6; 2%, n = 12), MS + MR (8%, n = 13; 4%, n = 28), and ejection fraction (48%, 56%). Operative procedures in Groups 1 and 2 were MV repair (54%, n = 84; 89%, n = 645) and MV replacement (46%, n = 70; 11%, n = 82). Circulatory management techniques for Groups 1 and 2 included endoballoon (75%, n = 116; 79%, n = 576), Chitwood clamp (8%, n = 12; 20%, n = 147), and fibrillatory arrest (17%, n = 30; 0.5%, n = 4). Perioperative outcomes were: stroke: 2.5%, 1.6%; reoperation for bleeding: 5%, 6%; valvular reoperation rate: 0.6%, 2%; aortic dissection: 2.5%, 1%; and wound infection: 0%, 0%. Transfusion requirement was 49% (n = 76) and 31% (n = 232), respectively. Median hospital stay was seven and seven days, respectively. On postoperative echocardiography, 98% (n = 151) and 99% (n = 718) of patients had zero or trace MR (1+) with 100% freedom from MR > 2+. In-hospital mortality was 3% (n = 5) and 1% (n = 8).

CONCLUSIONS

Operative outcomes with minimally invasive mitral valve surgery utilizing port access technology can be performed safely. Stroke rate was higher in the reoperative cases (p = NS) although similar to reports evaluating redo sternotomy in mitral valve cases.

Для цитирования: Vallabhajosyula Prashanth, Wallen Tyler J, Solometo Lauren P, Fox Jeanne, Vernick William J, Hargrove W Clark. Minimally invasive mitral valve surgery utilizing heart port technology.. Journal of cardiac surgery. 2014. DOI: 10.1111/jocs.12293.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.