MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-018-0684-7

Медицинская библиотека · BMC ophthalmology · 2018

Spontaneous reattachment of dislocated endothelial graft after non-Descemet stripping automated endothelial keratoplasty: a case report.

Kodama-Takahashi Aya, Fukuda Masahiko, Sugioka Koji, Kobayashi Akira, Shimomura Yoshikazu

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Graft detachment is a complication of non-Descemet stripping automated endothelial keratoplasty (nDSAEK). We report a case of spontaneous reattachment of an extensively dislocated graft after nDSAEK.

CASE PRESENTATION: A 54-year-old male underwent penetrating keratoplasty (PKP) for keratoconus in his left eye in 2001. Following graft opacity due to rejection, a second PKP was implemented in May 2014. The graft was kept in good condition after the reoperation and yet, visual acuity (VA) declined due to cataract. PEA+IOL was then performed in May 2015. Because edema appeared in the graft 6 months after the PEA+IOL, nDSAEK was carried out in May 2016. Although the donor graft well attached immediately after the nDSAEK, the graft was almost completely dislocated 3 h later except a temporal part. Air was reinjected into the anterior chamber on the following day and the detachment was resolved. Despite of the treatment, about 1/5 of the graft remained detached and the detachment deteriorated to 3/4 of the graft 9 days later. Because the patient could not decide whether to undergo another operation immediately, we decided to follow him up first and found that the partially detached graft reattached spontaneously 1 month later during the follow-up. Although the cornea had a mild edema remaining in the superior temporal area, his BCVA improved to 1.0. Three months later, the graft remained in position and the cornea kept its transparency.

CONCLUSIONS

Spontaneous reattachment was observed during the follow-up in a case that had shown a comparatively extensive graft dislocation after nDSAEK.

Для цитирования: Kodama-Takahashi Aya, Fukuda Masahiko, Sugioka Koji, Kobayashi Akira, Shimomura Yoshikazu. Spontaneous reattachment of dislocated endothelial graft after non-Descemet stripping automated endothelial keratoplasty: a case report.. BMC ophthalmology. 2018. DOI: 10.1186/s12886-018-0684-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.