MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjophth-2017-000090

Медицинская библиотека · BMJ open ophthalmology · 2017

Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).

Doroodgar Farideh, Niazi Feazollah, Sanginabadi Azad, Niazi Sana, Baradaran-Rafii Alireza, Alinia Cyrus, Azargashb Eznollah, Ghoreishi Mohammad

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To report on 4-year postoperative visual performance with the toric implantable collamer lens (TICL) for stable keratoconus after sequential procedure (corneal collagen crosslinking plus TICL implantation).

METHODS

Forty eyes of 24 patients with stable keratoconus with myopia between 0.00 and -18.00 dioptres (D) and astigmatism between 1.25 and 8.00 D were evaluated in this prospective interventional study (https://clinicaltrials.gov/ct2/show/NCT02833649). We evaluated refraction, visual outcomes, astigmatic changes analysed by Alpins vector, contrast sensitivity, aberrometry, modulation transfer functions (MTFs), defocus curve, and operative and postoperative complications.

RESULTS

At 4-year follow-up, 45% had 20/20 vision or better and 100% had 20/40 or better uncorrected visual acuity (UCVA). Vector analysis of refractive astigmatism shows that the surgically induced astigmatism (SIA) (3.20±1.46 D) was not significantly different from the target induced astigmatism (TIA) (3.14±1.42 D) (p=0.620). At 4 years postoperatively, none of the eyes showed a decrease in UCVA, in contrast to 24 eyes in which UCVA was increased by ≥1 lines, with contrast sensitivity and improvement in total aberrations and MTF value at 5 per degree (*p=0.004) after TICL implantation. The cumulative 4-year corneal endothelial cell loss was ≤5%. No patients reported dissatisfaction. At the end of follow-up, the vault was 658±54.33m (range, 500-711) and the intraocular pressure was 11.7±2.08 mm Hg. Occurrences of glare and night-driving troubles diminished after TICL surgery.

CONCLUSION

The results from this standardised clinical investigation support TICL implantation from clinical and optical viewpoints in patients with stable keratoconus.

TRIAL REGISTRATION NUMBER: NCT02833649, Pre-results.

Для цитирования: Doroodgar Farideh, Niazi Feazollah, Sanginabadi Azad, Niazi Sana, Baradaran-Rafii Alireza, Alinia Cyrus, Azargashb Eznollah, Ghoreishi Mohammad. Comparative analysis of the visual performance after implantation of the toric implantable collamer lens in stable keratoconus: a 4-year follow-up after sequential procedure (CXL+TICL implantation).. BMJ open ophthalmology. 2017. DOI: 10.1136/bmjophth-2017-000090.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.