MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/meajo.meajo_244_16

Медицинская библиотека · Middle East African journal of ophthalmology · 2017

Mesopic Quality of Vision after Accelerated 18 mW/cm2 Corneal Cross-linking: Mid-term Results.

Hashemi Hassan, Miraftab Mohammad, Asgari Soheila

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of the study was to determine 2-year changes in mesopic higher-order aberrations (HOAs) and contrast sensitivity (CS) after accelerated corneal cross-linking (CXL) in keratoconus patients.

MATERIALS AND

METHODS

In this before-after interventional case series, patients with progressive keratoconus were subjected to accelerated CXL (18 mW/cm2, 5 min). Patients were examined with the OPD-Scan III and CVS-1000 grating charts under mesopic conditions at baseline and at 12 and 24 months after CXL.

RESULTS

At 24 months after CXL, compared to baseline, mesopic CS in spatial frequencies of 3, 6, 12, and 18 cycle per degree reduced respectively to 0.09 ± 0.27, 0.09 ± 0.32, 0.11 ± 0.19, and 0.02 ± 0.10; these changes were not statistically significant (all P > 0.05). The reduction in ocular HOAs was 0.11 ± 0.43; ocular coma, trefoil, and spherical aberration (SA) decreased by 0.09 ± 0.36, 0.05 ± 0.35, and 0.00 ± 0.13 microns, respectively (all P > 0.05). Reductions in corneal HOAs (0.89 ± 7.08) including coma (0.99 ± 3.55), SA (1.14 ± 3.92), and trefoil (1.28 ± 5.53) were not statistically significant (all P > 0.05). Coma had the highest share of corneal HOAs before and 24 months after CXL and the largest 24-month decrease was seen in corneal SA.

CONCLUSION

At 2 years after accelerated CXL, despite reduced keratometry and corneal flattening, mesopic CS as well as ocular and corneal HOA remained unchanged, and the procedure did not cause a reduction in patients' vision quality.

Для цитирования: Hashemi Hassan, Miraftab Mohammad, Asgari Soheila. Mesopic Quality of Vision after Accelerated 18 mW/cm2 Corneal Cross-linking: Mid-term Results.. Middle East African journal of ophthalmology. 2017. DOI: 10.4103/meajo.meajo_244_16.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.