PURPOSE: To test the hypothesis that marginal ray deviations determine perceived starburst sizes, and to explore different strategies for decreasing starburst size in highly aberrated eyes.

METHODS

Perceived size of starburst images and visual acuities were measured psychophysically for eyes with varying levels of spherical aberration, pupil sizes, and defocus. Computationally, we use a polychromatic eye model including the typical levels of higher order aberrations (HOAs) for keratoconic and post-LASIK eyes to quantify the image quality (the visually weighted Strehl ratio derived from the optical transfer function, VSOTF) with different pupil sizes at both photopic and mesopic light levels.

RESULTS

For distance corrected post-LASIK and keratoconic eyes with a night-time pupil (e.g., 7 mm), the starburst diameter is about 1.5 degrees (1 degree for normal presbyopic eyes), which can be reduced to ≤0.25 degrees with pupil sizes ≤3 mm. Starburst size is predicted from the magnitude of the longitudinal spherical aberration. Refracting the eye to focus the pupil margin also removed starbursts, but, unlike small pupils, significantly degraded visual acuity. Reducing pupil diameter to 3 mm improved image quality for these highly aberrated eyes by about 2.7 ×  to 1.7 ×  relative to the natural pupils when light levels were varied from 0.1 to 1000 cd m-2 , respectively.

CONCLUSION

Subjects with highly aberrated eyes observed larger starbursts around bright lights at night predictable by the deviated marginal rays. These were effectively attenuated by reducing pupil diameters to ≤3 mm, which did not cause a drop in visual acuity or modelled image quality even at mesopic light levels.

Для цитирования: Xu Renfeng, Kollbaum Pete, Thibos Larry, Lopez-Gil Norberto, Bradley Arthur. Reducing starbursts in highly aberrated eyes with pupil miosis.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2018. DOI: 10.1111/opo.12420.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.