MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clae.2017.12.013

Медицинская библиотека · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2017

Effects of the rigid gas permeable contact lense use on tear and ocular surface among keratoconus patients.

Yuksel Elgin Cansu, Iskeleli Guzin, Aydin Ovgu

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate changes in tear and ocular surface of patients with keratoconus using rigid gas permeable contact lenses (RGPCL) and compare them against keratoconus patients who were not using lenses as well as a control group of healthy subjects.

METHODS

24 keratoconus patients using RGPCL (Group 1) 22 patients who were not using lenses (Group 3) and 21 healthy subjects (Group 3) were included in the study. Subjective complaints about the subjects' eyes have been investigated using the ocular-surface disease index (OSDI). After the control of best-corrected visual acuity, anterior chamber and fundus examinations were performed.

RESULTS

Schirmer (p-value=0.01) and tear break up mean comparison tests (p-value=0.002) revealed significant differences across different groups but tear osmolarity analysis did not (p-value >0.05). Oxford and OSDI scores were compatible with Schirmer and tear break up test comparisons. (for both p-value=0.001) Moreover, no statistical differences were seen in impression cytology measures between groups. (p-value >0.05)

CONCLUSIONS

The erosion in the tear film stability is in line with the erosion in the ocular surface epithelium. Taking into account the statistical indifference between the impression cytology measures across groups, the break up time differences may be attributed to the collagen destruction in tear.

Для цитирования: Yuksel Elgin Cansu, Iskeleli Guzin, Aydin Ovgu. Effects of the rigid gas permeable contact lense use on tear and ocular surface among keratoconus patients.. Contact lens & anterior eye : the journal of the British Contact Lens Association. 2017. DOI: 10.1016/j.clae.2017.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.