MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.11101860

Медицинская библиотека · Radiology · 2011

Idiopathic normal-pressure hydrocephalus: temporal changes in ADC during cardiac cycle.

Ohno Naoki, Miyati Tosiaki, Mase Mitsuhito, Osawa Tomoshi, Kan Hirohito, Kasai Harumasa, Hara Masaki, Shibamoto Yuta, Hayashi Norio, Gabata Toshifumi, Matsui Osamu

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine whether temporal changes in apparent diffusion coefficient (ADC) over the cardiac cycle are different in patients with idiopathic normal-pressure hydrocephalus (INPH) as compared with patients with ex vacuo ventricular dilatation and healthy control subjects.

MATERIALS AND

METHODS

This prospective study was approved by the institutional review board and was performed only after informed consent was obtained from each patient. At 1.5 T, electrocardiographically triggered single-shot diffusion echo-planar magnetic resonance imaging (b = 0 and 1000 sec/mm(2)) was performed with sensitivity encoding and half-scan techniques to minimize bulk motion. ΔADC was defined as the difference between maximum and minimum ADC on a pixel-by-pixel basis over 20 phases of the cardiac cycle. Mean ADC during the diastolic phase and ΔADC in the frontal white matter were determined in patients with INPH (n = 13), patients with ex vacuo ventricular dilatation (n = 8), and healthy volunteers (n = 10). Kruskal-Wallis tests were used to determine significance between groups.

RESULTS

Mean ΔADC in the INPH group was significantly higher than that in the ex vacuo ventricular dilatation and control groups (P < .01 for both). There was no significant difference in ΔADC between the ex vacuo ventricular dilatation and control groups (P = .86). There was no significant difference in mean ADC during the diastolic phase among groups (P > .05 for all). There was no significant correlation between ΔADC and mean ADC during the diastolic phase in any group.

CONCLUSION

Determination of fluctuation of ADC over the cardiac cycle may render it possible to noninvasively obtain new and more detailed information than that provided by standard ADC measurement in suspected INPH, potentially facilitating the diagnosis of this disease.

Для цитирования: Ohno Naoki, Miyati Tosiaki, Mase Mitsuhito, Osawa Tomoshi, Kan Hirohito, Kasai Harumasa, Hara Masaki, Shibamoto Yuta, Hayashi Norio, Gabata Toshifumi, Matsui Osamu. Idiopathic normal-pressure hydrocephalus: temporal changes in ADC during cardiac cycle.. Radiology. 2011. DOI: 10.1148/radiol.11101860.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.