A new approach to keratoconus detection based on corneal morphogeometric analysis.

Cavas-Martínez Francisco, Bataille Laurent, Fernández-Pacheco Daniel G, Cañavate Francisco J F, Alió Jorge L

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To characterize corneal structural changes in keratoconus using a new morphogeometric approach and to evaluate its potential diagnostic ability.

METHODS

Comparative study including 464 eyes of 464 patients (age, 16 and 72 years) divided into two groups: control group (143 healthy eyes) and keratoconus group (321 keratoconus eyes). Topographic information (Sirius, CSO, Italy) was processed with SolidWorks v2012 and a solid model representing the geometry of each cornea was generated. The following parameters were defined: anterior (Aant) and posterior (Apost) corneal surface areas, area of the cornea within the sagittal plane passing through the Z axis and the apex (Aapexant, Aapexpost) and minimum thickness points (Amctant, Amctpost) of the anterior and posterior corneal surfaces, and average distance from the Z axis to the apex (Dapexant, Dapexpost) and minimum thickness points (Dmctant, Dmctpost) of both corneal surfaces.

RESULTS

Significant differences among control and keratoconus group were found in Aapexant, Aapexpost, Amctant, Amctpost, Dapexant, Dapexpost (all p<0.001), Apost (p = 0.014), and Dmctpost (p = 0.035). Significant correlations in keratoconus group were found between Aant and Apost (r = 0.836), Amctant and Amctpost (r = 0.983), and Dmctant and Dmctpost (r = 0.954, all p<0.001). A logistic regression analysis revealed that the detection of keratoconus grade I (Amsler Krumeich) was related to Apost, Atot, Aapexant, Amctant, Amctpost, Dapexpost, Dmctant and Dmctpost (Hosmer-Lemeshow: p>0.05, R2 Nagelkerke: 0.926). The overall percentage of cases correctly classified by the model was 97.30%.

CONCLUSIONS

Our morphogeometric approach based on the analysis of the cornea as a solid is useful for the characterization and detection of keratoconus.

Для цитирования: Cavas-Martínez Francisco, Bataille Laurent, Fernández-Pacheco Daniel G, Cañavate Francisco J F, Alió Jorge L. A new approach to keratoconus detection based on corneal morphogeometric analysis.. PloS one. 2017. DOI: 10.1371/journal.pone.0184569.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.