Toric ICL Implantation After Sequential Intracorneal Ring Segments Implantation and Corneal Cross-linking in Keratoconus: 2-Year Follow-up.

Abdelmassih Youssef, El-Khoury Sylvain, Chelala Elias, Slim Elise, Cherfan Carole G, Jarade Elias

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate 6-month and 2-year safety and clinical outcomes of Visian toric Implantable Collamer Lens (toric ICL) (STAAR Surgical, Monrovia, CA) implantation for the treatment of residual refractive errors after sequential intracorneal ring segments (ICRS) insertion and cross-linking (CXL) in keratoconus.

METHODS

This consecutive case series included the results of a three-step ICRS-CXL-toric ICL procedure in 16 eyes of 13 patients with moderate to severe keratoconus (stages II and III of Amsler-Krumeich classification). The ICRS and CXL procedures were performed sequentially with an interval of 4 weeks and the toric ICL implantation was performed at least 6 months after CXL. Data were collected preoperatively, at 6 months after sequential ICRS-CXL, and at 6 and 24 months following toric ICL implantation. All 16 eyes were evaluated at the 2-year follow-up.

RESULTS

There was a significant decrease in keratometry (steep, flat, and maximum) and refraction (sphere and spherical equivalence, but not cylinder) and a significant increase in both uncorrected (UDVA) (from 1.06 to 0.76 logMAR, P = .004) and corrected (CDVA) (from 0.42 to 0.26 logMAR; P = .002) distance visual acuity 6 months following sequential ICRS-CXL, whereas UDVA and refraction significantly improved 6 months after ICL insertion (UDVA reached 0.33 logMAR, P = .001). At the 24-month follow-up, UDVA and keratometric readings were stable, whereas CDVA, sphere, and cylinder showed a significant improvement.

CONCLUSIONS

Implantation of Visian toric ICL following sequential ICRS insertion and CXL is an effective and safe option for correcting high residual refractive error and improving visual acuity in patients with moderate to severe keratoconus in the long term. [J Refract Surg. 2017;33(9):610-616.].

Для цитирования: Abdelmassih Youssef, El-Khoury Sylvain, Chelala Elias, Slim Elise, Cherfan Carole G, Jarade Elias. Toric ICL Implantation After Sequential Intracorneal Ring Segments Implantation and Corneal Cross-linking in Keratoconus: 2-Year Follow-up.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2017. DOI: 10.3928/1081597x-20170621-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.