MedElevator Войти в исследования
← Поиск публикаций

DOI 10.33963/kp.a2023.0152

Медицинская библиотека · Kardiologia polska · 2023

Safety and efficacy of a novel calcified plaque modification technique - Shockwave Intravascular Lithotripsy - in patients with coronary artery disease: Mid-term outcomes.

Rola Piotr, Furtan Łukasz, Włodarczak Szymon, Barycki Mateusz, Kędzierska Michalina, Doroszko Adrian, Włodarczak Adrian, Lesiak Maciej

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Coronary interventions in calcified lesions are associated with a higher rate of adverse clinical events. Initial aggressive plaque modification along with post-implantation optimization is pivotal for achieving a favorable outcome of percutaneous coronary intervention (PCI). Recently, the Shockwave C2 Intravascular Lithotripsy (S-IVL) System, a novel acoustic wave-based device designed to modify calcified plaque, has been introduced into clinical practice.

AIMS: We evaluated the mid-term safety and efficiency of S-IVL in a cohort of 131 consecutive patients with severely calcified coronary lesions.

METHODS

We retrospectively analyzed a total of 131 consecutive S-IVL PCI procedures. The study had two main inclusion criteria - the presence of a calcified resistant lesion (defined by inadequate non-compliant balloon catheter inflation) or a significantly underexpanded stent (more than 20% of reference diameter). The study had two primary endpoints - successful clinical outcome and safety concerns. Clinical success was defined as effective stent deployment or optimization of a previously underexpanded stent (with less than <20% in-stent residual stenosis). Safety outcomes were defined as periprocedural complications, such as device failure and major adverse cardiac and cerebrovascular events (MACCE). Clinical follow-up was performed at the end of hospitalization and 6 months after the index procedure.

RESULTS

In-hospital MACCE was 4.6% with 1.5% target lesion revascularization (TLR) and one case of subacute fatal stent thrombosis. At 6-month follow-up, the MACCE rate was 7.9% with a concomitant TLR rate of 3.8%.

CONCLUSION

Our mid-term data confirm acceptable safety and efficacy of intravascular lithotripsy as a valuable strategy for lesion preparation and stent optimization in a cohort of 131 consecutive patients with severely calcified coronary lesions.

Для цитирования: Rola Piotr, Furtan Łukasz, Włodarczak Szymon, Barycki Mateusz, Kędzierska Michalina, Doroszko Adrian, Włodarczak Adrian, Lesiak Maciej. Safety and efficacy of a novel calcified plaque modification technique - Shockwave Intravascular Lithotripsy - in patients with coronary artery disease: Mid-term outcomes.. Kardiologia polska. 2023. DOI: 10.33963/kp.a2023.0152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.