MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ajcp/aqw208

Медицинская библиотека · American journal of clinical pathology · 2017

Diagnostic Utility of Lymphoid Enhancer Binding Factor 1 Immunohistochemistry in Small B-Cell Lymphomas.

Menter Thomas, Trivedi Pritesh, Ahmad Raida, Flora Rashpal, Dirnhofer Stephan, Tzankov Alexandar, Naresh Kikkeri N

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Recent studies have shown that lymphoid enhancer binding factor 1 (LEF1) is a useful marker for chronic lymphocytic B-cell leukemia (CLL)/small lymphocytic lymphoma. Yet, it is not still being widely used in a diagnostic setting. In this study, we document the experience with LEF1 immunohistochemistry during routine diagnostics.

METHODS

In total, 191 B-cell lymphoma cases from Hammersmith Hospital, Imperial College NHS Healthcare Trust (London, UK) were investigated by immunohistochemistry for LEF1 during routine diagnostic workup. These cases included both bone marrow trephines and lymph node biopsy specimens. The monoclonal antibody clone EPR2029Y was used.

RESULTS

LEF1 expression was strong and diffuse (>70% of cells) in most cases. Few CLL cases showed a staining in proliferation centers only. Seventy-seven of 80 CLL cases expressed LEF1. Other entities expressing LEF1 included one of 38 follicular lymphomas, two of 33 marginal zone lymphomas, and one diffuse large B-cell lymphoma with a background of follicular lymphoma grade 3B. Sensitivity for LEF1 for the diagnosis of CLL was 0.96, and specificity was 0.93.

CONCLUSIONS

In this study, we could demonstrate the diagnostic utility of LEF1. LEF1 is a sensitive and specific marker for CLL and is helpful in the diagnosis of diagnostically challenging small B-cell lymphomas.

Для цитирования: Menter Thomas, Trivedi Pritesh, Ahmad Raida, Flora Rashpal, Dirnhofer Stephan, Tzankov Alexandar, Naresh Kikkeri N. Diagnostic Utility of Lymphoid Enhancer Binding Factor 1 Immunohistochemistry in Small B-Cell Lymphomas.. American journal of clinical pathology. 2017. DOI: 10.1093/ajcp/aqw208.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.