Severe occlusive carotid artery disease: hemodynamic assessment by MR perfusion imaging in symptomatic patients.
Аннотация
BACKGROUND AND PURPOSE: Cerebral hemodynamic status has been reported to influence the occurrence and outcome of acute stroke. The purpose of this study was to assess hemodynamic compromise in symptomatic patients with severe occlusive disease of the carotid artery by the use of echo-planar perfusion imaging.
METHODS
Spin-echo echo-planar perfusion imaging was performed in 11 patients (two had bilateral disease) with severe stenosis or occlusion of the carotid artery who had experienced either a recent transient ischemic attack or minor stroke. Relative cerebral blood volume (rCBV) maps and relative mean transit time (rMTT) maps were generated from the time-concentration curve. Findings on T2-weighted images, angiograms, rCBV maps, and rMTT maps were compared and assessed qualitatively and quantitatively.
RESULTS
Although the abnormalities on T2-weighted images were absent, minimal, and/or unrelated to the degree of stenosis or collateral circulation, rMTT maps showed much larger and more distinct perfusion abnormalities along the vascular distribution of the affected vessels in all 13 vascular territories of the 11 patients. Despite obvious abnormalities on rMTT maps, none of the patients had evidence of decreased rCBV in the affected brain tissue (increased in three, normal in eight). A statistically significant difference in rMTT values was found between the affected and unaffected brain tissue, whereas no significant difference was seen in rCBV values.
CONCLUSION
Echo-planar perfusion imaging is a noninvasive and rapid method for evaluating the hemodynamics in severe occlusive carotid artery disease and the compensatory vascular changes, and it may be useful in patient management.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.