m+Medelevator.RU
← Поиск публикаций
The Journal of urology · 2003

Obtaining rigidity in total phalloplasty: experience with 35 patients.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hoebeke P, de Cuypere G, Ceulemans P, Monstrey S

Аннотация

PURPOSE: The combination of a neourethra and erection prosthesis in a single neophallus in the female-to-male transsexual remains a challenge. The outcome reported in the literature is disappointing. We report our experience with 35 patients.

MATERIALS AND METHODS: Between August 1996 and December 2001, 35 patients underwent implantation surgery. A 1-piece hydraulic Dynaflex prosthesis (American Medical Systems, Minnetonka, Minnesota) was used in 10 patients, while a 3-piece hydraulic CXM and CX (American Medical Systems) prosthesis was placed in 9 and 16, respectively. The 1-piece model was withdrawn from the market in 1997. Thereafter a 3-piece prosthesis was implanted.

RESULTS: Of 10 patients in the 1-piece group prosthesis implantation was uneventful in 8. In 2 patients with technical failure the prosthesis was replaced, including 1 in whom the new prosthesis was removed due to infection and successfully replaced by a 3-piece prosthesis. To date at a mean followup of 3.5 years 9 patients have a 1-piece hydraulic prosthesis in place. In the 3-piece prosthesis group of 25 patients implantation was uneventful in 20. In 1 patient infection and partial necrosis of the neophallus developed, 2 had infection, in 1 a cylinder perforated the tip of the phallus and in 1 technical failure occurred. Of the latter 4 patients the prosthesis was replaced successfully in 2 patients, while the other 2 are on the waiting list. The patient with partial necrosis of the phallus is no longer a candidate for an erection prosthesis. To date at a mean followup of 1.8 years 23 patients have a 3-piece hydraulic prosthesis in place. A single patient in the 1-piece group has a 3-piece CX prosthesis.

CONCLUSIONS: Good results were observed after implantation of the Dynaflex prosthesis in patients who underwent total phalloplasty. This model is no longer available today. For the more complex 3-piece CX and CXM prostheses implantation results are comparable to those of the 1-piece model.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты