Radiation medicine · 2003
Coronal multiplanar reconstruction view from isotropic voxel data sets obtained with multidetector-row CT: assessment of detection and size of mediastinal and hilar lymph nodes.
Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kozuka Takenori, Tomiyama Noriyuki, Johkoh Takeshi, Honda Osamu, Koyama Mitsuhiro, Hamada Seiki, Nakamura Hironobu, Yamamoto Shuji, Matsumoto Takashi
Аннотация
OBJECTIVE: To assess the detection and size of mediastinal and hilar lymph nodes by multiplanar reconstruction (MPR) view from isotropic voxel data sets obtained with multidetector-row computed tomography (MDCT).
MATERIALS AND METHODS: Thin-section CT of 27 patients with mediastinal or hilar lymph node swelling was obtained with a 25.6-cm FOV, 512 x 512 matrix, and two protocols: A) 0.5-mm collimation, 0.3-mm interval, and B) 2-mm collimation, 1-mm interval. MPR views with a 0.5-mm slice thickness were obtained from these two data sets. Postcontrast axial CT used 5-mm collimation (set C). Two observers evaluated the presence and cranio-caudal length of swollen lymph nodes. Two other board-certified chest radiologists evaluated all three sets and established a gold standard by consensus.
RESULTS: The accuracy of detection was 76%, 73%, and 68% for sets A, B, and C, respectively. There was a significant difference between sets A and C (McNemar's test: p<0.05) but not between sets A and B or B and C (p>0.05). The cranio-caudal length of lymph nodes was significantly correlated with the gold standard only in set A (Pearson's correlation coefficient: r=0.53, p<0.05).
CONCLUSION: Non-contrast enhanced coronal MPR views constructed from isotropic voxel data sets may be substituted for axial enhanced CT for the evaluation of mediastinal and hilar lymph nodes.
MATERIALS AND METHODS: Thin-section CT of 27 patients with mediastinal or hilar lymph node swelling was obtained with a 25.6-cm FOV, 512 x 512 matrix, and two protocols: A) 0.5-mm collimation, 0.3-mm interval, and B) 2-mm collimation, 1-mm interval. MPR views with a 0.5-mm slice thickness were obtained from these two data sets. Postcontrast axial CT used 5-mm collimation (set C). Two observers evaluated the presence and cranio-caudal length of swollen lymph nodes. Two other board-certified chest radiologists evaluated all three sets and established a gold standard by consensus.
RESULTS: The accuracy of detection was 76%, 73%, and 68% for sets A, B, and C, respectively. There was a significant difference between sets A and C (McNemar's test: p<0.05) but not between sets A and B or B and C (p>0.05). The cranio-caudal length of lymph nodes was significantly correlated with the gold standard only in set A (Pearson's correlation coefficient: r=0.53, p<0.05).
CONCLUSION: Non-contrast enhanced coronal MPR views constructed from isotropic voxel data sets may be substituted for axial enhanced CT for the evaluation of mediastinal and hilar lymph nodes.