MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.120.6.1803

Медицинская библиотека · Chest · 2001

Effects of proton and combined proton/photon beam radiation on pulmonary function in patients with resectable but medically inoperable non-small cell lung cancer.

Bonnet R B, Bush D, Cheek G A, Slater J D, Panossian D, Franke C, Slater J M

Клиническое исследованиеКлиническое исследование I фазыКлиническое исследование II фазыСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVES

We evaluated the effects on pulmonary function of irradiating lung cancer with protons alone or protons combined with photons.

DESIGN

Prospective phase I/II study.

SETTING

University medical center.

PATIENTS AND INTERVENTIONS: Ten patients with stage I-II non-small cell lung cancer (NSCLC) and FEV(1) < or = 1.0 L were irradiated with protons to areas of gross disease only, using 51 cobalt gray equivalents (CGE) in 10 fractions (protocol 1). Fifteen patients with stage I-IIIA NSCLC and FEV(1) > 1.0 L received 45-Gy photon irradiation to the primary lung tumor and the mediastinum, plus a 28.8-CGE proton boost to the gross tumor volume (protocol 2).

MEASUREMENTS: Pulmonary function was evaluated prior to treatment and 1 month, 3 months, and 6 to 12 months following irradiation.

RESULTS

In patients receiving protocol 1, no significant changes in pulmonary function occurred. In patients receiving protocol 2, at 6 to 12 months, the diffusion capacity of the lung for carbon monoxide had declined from 61% of predicted to 45% of predicted (p < 0.05), total lung capacity had declined from 114% of predicted to 95% of predicted (p < 0.05), and residual volume had declined from 160% of predicted to 132% of predicted (p < 0.05). Airway resistance increased from 3.8 to 5.2 cm H(2)O/L/s (p < 0.05). No statistically significant changes occurred in vital capacity, FEV(1), or PaO(2).

CONCLUSIONS

Our observations indicate that it is feasible to apply higher-than-conventional doses of radiation at a higher-than-conventional dose per fraction without excess pulmonary toxicity when conformal radiation techniques with protons are used.

Для цитирования: Bonnet R B, Bush D, Cheek G A, Slater J D, Panossian D, Franke C, Slater J M. Effects of proton and combined proton/photon beam radiation on pulmonary function in patients with resectable but medically inoperable non-small cell lung cancer.. Chest. 2001. DOI: 10.1378/chest.120.6.1803.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.