m+Medelevator.RU
← Поиск публикаций
Journal of periodontal research · 2021

Survival rate and potential risk indicators of implant loss in non-smokers and systemically healthy periodontitis patients: An up to 9-year retrospective study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Yiwei, Fan Yadan, Lin Zhikai, Song Zhongchen, Shu Rong, Xie Yufeng

Аннотация

BACKGROUND: An increasing number of patients with chronic periodontitis (CP) have received implant restoration. However, very few studies have evaluated the probable risk indicators of implant loss in patients with CP.

OBJECTIVE: The aim of this study is to evaluate implant long-term survival rates in patients with CP. The results are analyzed to discern potential risk indicators of implant loss.

METHODS: A total of 1549 implants were inserted in 827 non-smokers and systemically healthy CP patients between March 2011 and March 2019. Clinical variables (age; sex; implant location; implant diameter; implant length; implant type; bone quality; bone graft, periodontal disease status, and insertion torque) were recorded. Kaplan-Meier survival curves illustrated the cumulative survival rate. The relationship between variables and implant loss was discerned by univariate analysis. Further multivariate Cox proportional hazard regression analysis was carried out for the variables with P < 0.2.

RESULTS: The cumulative survival rates were 98.8% after 3 months, 97.9% after 6 months, 97.7% after 1 year, and 97.4% after 2 to 9 years. After adjusting possible confounders, the multivariable Cox regression model revealed statistically significant influences of implant location, history of bone graft, and insertion torque on implant loss. Implants with history of bone graft were more likely to loss. Implants inserted in the anterior area had a higher implant loss risk; insertion torque of <15 Newton-centimeter (Ncm) showed a relatively high risk of being lost.

CONCLUSIONS: The study represented public hospital insight into long-term implant results of patients with CP. Under the premise of strict periodontal control, patients with the history of CP exhibited relatively high implant survival rate. Anterior implant location, history of bone graft, and insertion torque <15 Ncm are associated with a lower implant survival rate and could be considered at a higher risk of implant failure in patients with CP.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты