MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtos.2022.06.006

Медицинская библиотека · The ocular surface · 2022

Automated quantification of meibomian gland dropout in infrared meibography using deep learning.

Saha Ripon Kumar, Chowdhury A M Mahmud, Na Kyung-Sun, Hwang Gyu Deok, Eom Youngsub, Kim Jaeyoung, Jeon Hae-Gon, Hwang Ho Sik, Chung Euiheon

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Develop a deep learning-based automated method to segment meibomian glands (MG) and eyelids, quantitatively analyze the MG area and MG ratio, estimate the meiboscore, and remove specular reflections from infrared images.

METHODS

A total of 1600 meibography images were captured in a clinical setting. 1000 images were precisely annotated with multiple revisions by investigators and graded 6 times by meibomian gland dysfunction (MGD) experts. Two deep learning (DL) models were trained separately to segment areas of the MG and eyelid. Those segmentation were used to estimate MG ratio and meiboscores using a classification-based DL model. A generative adversarial network was implemented to remove specular reflections from original images.

RESULTS

The mean ratio of MG calculated by investigator annotation and DL segmentation was consistent 26.23% vs 25.12% in the upper eyelids and 32.34% vs. 32.29% in the lower eyelids, respectively. Our DL model achieved 73.01% accuracy for meiboscore classification on validation set and 59.17% accuracy when tested on images from independent center, compared to 53.44% validation accuracy by MGD experts. The DL-based approach successfully removes reflection from the original MG images without affecting meiboscore grading.

CONCLUSIONS

DL with infrared meibography provides a fully automated, fast quantitative evaluation of MG morphology (MG Segmentation, MG area, MG ratio, and meiboscore) which are sufficiently accurate for diagnosing dry eye disease. Also, the DL removes specular reflection from images to be used by ophthalmologists for distraction-free assessment.

Для цитирования: Saha Ripon Kumar, Chowdhury A M Mahmud, Na Kyung-Sun, Hwang Gyu Deok, Eom Youngsub, Kim Jaeyoung, Jeon Hae-Gon, Hwang Ho Sik, Chung Euiheon. Automated quantification of meibomian gland dropout in infrared meibography using deep learning.. The ocular surface. 2022. DOI: 10.1016/j.jtos.2022.06.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.