Minerva anestesiologica · 2026
Predictive value of Hypotension Prediction Index in liver transplantation: a prospective study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yeh Bo-Han, Lu Yu-Chieh, Liu Fu-Chao, Tsai Hsin-I, Lin Chih-Chung, Chen Chun-Yu, Lee Wei-Chen, Tsai Yung-Fong
Аннотация
BACKGROUND: Intraoperative hypotension (IOH) is associated with increased postoperative morbidity and mortality. This prospective study evaluated the predictive accuracy of the Hypotension Prediction Index (HPI), an artificial intelligence-based algorithm, for predicting IOH during liver transplantation (LT).
METHODS: Twenty-one adult patients undergoing LT for liver cirrhosis and/or hepatocellular carcinoma were enrolled in this study. Under general anesthesia, arterial pressure waveform data were collected using Acumen IQ transducers and transmitted to the HPI monitor for continuous hemodynamic monitoring. Hemodynamic data were recorded at 20-second intervals, resulting in 34,592 data points. Analyses were conducted for the overall cohort and across LT phases (preanhepatic, anhepatic, neohepatic) and stratified using a Model for End-Stage Liver Disease (MELD) score threshold of 15. Predictive performance was assessed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity.
RESULTS: HPI demonstrated significant predictive capability, with an overall AUC of 94.2% (95% CI: 94.0-94.5) for IOH prediction within five minutes before hypotensive events. Sensitivity and specificity were 91.7% (95% CI: 91.2-92.3) and 77.5% (95% CI: 76.9-78.0), respectively. Subgroup analyses showed AUCs ranging from 86.0% to 96.3% across different LT phases. In patients with MELD score ≥15, the HPI maintained high predictive accuracy, with an AUC of 94.2% (95% CI: 93.8-94.5).
CONCLUSIONS: The HPI reliably predicts IOH during LT and may support early intervention strategies to mitigate perioperative haemodynamic instability.
METHODS: Twenty-one adult patients undergoing LT for liver cirrhosis and/or hepatocellular carcinoma were enrolled in this study. Under general anesthesia, arterial pressure waveform data were collected using Acumen IQ transducers and transmitted to the HPI monitor for continuous hemodynamic monitoring. Hemodynamic data were recorded at 20-second intervals, resulting in 34,592 data points. Analyses were conducted for the overall cohort and across LT phases (preanhepatic, anhepatic, neohepatic) and stratified using a Model for End-Stage Liver Disease (MELD) score threshold of 15. Predictive performance was assessed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity.
RESULTS: HPI demonstrated significant predictive capability, with an overall AUC of 94.2% (95% CI: 94.0-94.5) for IOH prediction within five minutes before hypotensive events. Sensitivity and specificity were 91.7% (95% CI: 91.2-92.3) and 77.5% (95% CI: 76.9-78.0), respectively. Subgroup analyses showed AUCs ranging from 86.0% to 96.3% across different LT phases. In patients with MELD score ≥15, the HPI maintained high predictive accuracy, with an AUC of 94.2% (95% CI: 93.8-94.5).
CONCLUSIONS: The HPI reliably predicts IOH during LT and may support early intervention strategies to mitigate perioperative haemodynamic instability.