Comparison of strategies for grading retinal images of premature infants for referral warranted retinopathy of prematurity.

Rogers David L, Bremer Don L, Fellows Rae R, Baumritter Agnieshka, Daniel Ebenezer, Pastilli Max, Ying Gui-Shang, Quinn Graham E, e-ROP Cooperative Group

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the accuracy of identifying referral-warranted retinopathy of prematurity (RW-ROP, defined as any zone I ROP, stage 3 or worse, or plus disease) from retinal image sets using three grading protocols: a single optic disk-centered image, a set of 3 horizontal images, and a 5-image set.

METHODS

In this secondary analysis of images from the e-ROP study, a weighted sample of 250 image sets from 250 infants (125 with RW-ROP and 125 without RW-ROP) was randomly selected. The sensitivities and specificities for detecting RW-ROP and its components from a single disk center image, along with nasal and temporal retinal images, were calculated and compared with the e-ROP grading of RW-ROP of all 5 retinal images (disk center and nasal, temporal, superior, and inferior retinal images).

RESULTS

RW-ROP was identified with a sensitivity of 11.2% (95% CI, 6.79%-17.9%) using a single disk center image, with a sensitivity of 70.4% (95% CI, 61.9%-77.9%) using 3 horizontal images, and a statistically higher sensitivity of 82.4% (95% CI, 75.0%-89.0%) using all 5 images (P = 0.002). The specificities were 100%, 86.4%, and 90.4%, respectively. For grading using 3 horizontal images, sensitivity was 14.3% for plus disease, 25% for zone I ROP, and 71.2% for stage 3 or worse compared to 40.8%, 50%, and 79.8% for grading using 5-image sets, respectively.

CONCLUSIONS

Both a single, disk-centered, posterior pole image and 3 horizontal images were less effective than a 5-image set in determining the presence of RW-ROP on qualitative grading by trained readers.

Для цитирования: Rogers David L, Bremer Don L, Fellows Rae R, Baumritter Agnieshka, Daniel Ebenezer, Pastilli Max, Ying Gui-Shang, Quinn Graham E, e-ROP Cooperative Group. Comparison of strategies for grading retinal images of premature infants for referral warranted retinopathy of prematurity.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2017. DOI: 10.1016/j.jaapos.2017.01.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.