Automated Grading System for Evaluation of Superficial Punctate Keratitis Associated With Dry Eye.

Rodriguez John D, Lane Keith J, Ousler George W, Angjeli Endri, Smith Lisa M, Abelson Mark B

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To develop an automated method of grading fluorescein staining that accurately reproduces the clinical grading system currently in use.

METHODS

From the slit lamp photograph of the fluorescein-stained cornea, the region of interest was selected and punctate dot number calculated using software developed with the OpenCV computer vision library. Images (n = 229) were then divided into six incremental severity categories based on computed scores. The final selection of 54 photographs represented the full range of scores: nine images from each of six categories. These were then evaluated by three investigators using a clinical 0 to 4 corneal staining scale. Pearson correlations were calculated to compare investigator scores, and mean investigator and automated scores. Lin's Concordance Correlation Coefficients (CCC) and Bland-Altman plots were used to assess agreement between methods and between investigators.

RESULTS

Pearson's correlation between investigators was 0.914; mean CCC between investigators was 0.882. Bland-Altman analysis indicated that scores assessed by investigator 3 were significantly higher than those of investigators 1 and 2 (paired t-test). The predicted grade was calculated to be: Gpred = 1.48log(Ndots) - 0.206. The two-point Pearson's correlation coefficient between the methods was 0.927 (P < 0.0001). The CCC between predicted automated score Gpred and mean investigator score was 0.929, 95% confidence interval (0.884-0.957). Bland-Altman analysis did not indicate bias. The difference in SD between clinical and automated methods was 0.398.

CONCLUSIONS

An objective, automated analysis of corneal staining provides a quality assurance tool to be used to substantiate clinical grading of key corneal staining endpoints in multicentered clinical trials of dry eye.

Для цитирования: Rodriguez John D, Lane Keith J, Ousler George W, Angjeli Endri, Smith Lisa M, Abelson Mark B. Automated Grading System for Evaluation of Superficial Punctate Keratitis Associated With Dry Eye.. Investigative ophthalmology & visual science. 2015. DOI: 10.1167/iovs.14-15318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.