The Journal of thoracic and cardiovascular surgery · 2002
One-year appraisal of a new aortic root conduit with sinuses of Valsalva.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
De Paulis Ruggero, De Matteis Giovanni Maria, Nardi Paolo, Scaffa Raffaele, Colella Dionisio F, Bassano Carlo, Tomai Fabrizio, Chiariello Luigi
Аннотация
OBJECTIVES: We evaluate the clinical results 1 year after an anatomic reconstruction of the aortic root in which we used a specifically designed aortic root prosthesis that incorporates the sinuses of Valsalva.
MATERIAL AND METHODS: The new aortic Dacron prosthesis has a proximal portion in the Dacron conduit that expands on implantation, creating pseudosinuses. During a 12-month period, 28 patients (mean age 59 +/- 14 years) underwent a Bentall operation (12 cases), a remodeling procedure (7 cases), and a reimplantation procedure (9 cases) with the use of a new aortic root conduit. All patients had aortic root aneurysm with an anatomically normal (for the valve-sparing procedure) or diseased aortic valve (for the Bentall operation). Five patients had aortic dissection and 5 had Marfan disease. The mean follow-up was 6 +/- 3 months. All patients underwent postoperative transesophageal and transthoracic echocardiographic studies.
RESULTS: All patients survived and were in good clinical condition at the latest follow-up. Postoperative echocardiography showed a marked reduction in ventricular volumes in all patient groups (P <.0005). In the Bentall group the new prosthesis appeared to reduce the tension on the coronary ostial sutures. In patients undergoing both types of valve-sparing procedures a similar normal anatomy of the aortic root was reconstructed. In the reimplantation group the anulus was smaller than in the remodeling group (P =.01). Patients undergoing the reimplantation procedure had less bleeding and a lower incidence of residual valve insufficiency.
CONCLUSIONS: The new aortic root prosthesis allowed the reconstruction of the aortic root anatomy in all types of surgical techniques with low postoperative morbidity.
MATERIAL AND METHODS: The new aortic Dacron prosthesis has a proximal portion in the Dacron conduit that expands on implantation, creating pseudosinuses. During a 12-month period, 28 patients (mean age 59 +/- 14 years) underwent a Bentall operation (12 cases), a remodeling procedure (7 cases), and a reimplantation procedure (9 cases) with the use of a new aortic root conduit. All patients had aortic root aneurysm with an anatomically normal (for the valve-sparing procedure) or diseased aortic valve (for the Bentall operation). Five patients had aortic dissection and 5 had Marfan disease. The mean follow-up was 6 +/- 3 months. All patients underwent postoperative transesophageal and transthoracic echocardiographic studies.
RESULTS: All patients survived and were in good clinical condition at the latest follow-up. Postoperative echocardiography showed a marked reduction in ventricular volumes in all patient groups (P <.0005). In the Bentall group the new prosthesis appeared to reduce the tension on the coronary ostial sutures. In patients undergoing both types of valve-sparing procedures a similar normal anatomy of the aortic root was reconstructed. In the reimplantation group the anulus was smaller than in the remodeling group (P =.01). Patients undergoing the reimplantation procedure had less bleeding and a lower incidence of residual valve insufficiency.
CONCLUSIONS: The new aortic root prosthesis allowed the reconstruction of the aortic root anatomy in all types of surgical techniques with low postoperative morbidity.