Efficacy and safety of repositioning malfunctioning peritoneal dialysis catheters with fluoroscopically guided guidewire manipulation.
Аннотация
OBJECTIVE
To evaluate the efficacy and safety of fluoroscopic-guided repositioning of peritoneal dialysis (PD) catheter using guidewire manipulation in our center in Hong Kong.
MATERIALS AND
METHODS
All patients underwent fluoroscopic-guided PD catheter repositioning in our institution between November 1, 2017 to December 31, 2022 were reviewed. Patients fulfilling the selection criteria were identified, with their clinical notes, relevant radiological reports, interventional images, and operative records retrospectively reviewed. The success rate was evaluated, with the technical success defined as improved free contrast flow or return of continuous steady stream after test injection of normal saline immediately after repositioning; clinical success defined as functional peritoneal dialysis catheter at 30 days post-repositioning. Logistic regression models were applied to evaluate the variables associated with successful manipulation. Post-manipulation complications and the PD time gained after successful manipulation were also reviewed.
RESULTS
46 patients were identified and 54 procedures were performed over the study period. 35 of the interventions (64.8%) resulted in technical success, and 25 cases (46.3%) resulted in clinical success. The median extra PD time gained after successful manipulation was 619 days (IQR, 313.5 - 1,007; range, 110 - 1,872). The median for number of days of hospital stay after the procedure was 2.5 days (IQR, 2 - 5; range, 1 - 65). Seven cases (13.0%) developed immediate complications, with most cases being peritonitis (n = 5), and all were successfully treated with intraperitoneal antibiotics. There was no associated mortality.
CONCLUSION
Fluoroscopic-guided repositioning of the PD catheter was found to be a useful and safe treatment option for malfunctioning PD catheter and could potentially spare patients from the conventional operative intervention.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.