m+Medelevator.RU
← Поиск публикаций
Current eye research · 2016

Value of Structural and Hemodynamic Parameters for the Early Detection of Primary Open-Angle Glaucoma.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kurysheva Natalia I, Parshunina Olga A, Shatalova Ekaterina O, Kiseleva Tatiana N, Lagutin Michael B, Fomin Alexey V

Аннотация

PURPOSE: To compare the diagnostic value of ocular blood flow parameters and choroidal thickness (CT) with standard structural parameters for early glaucoma detection.

METHODS: A total of 32 patients with pre-perimetric glaucoma were compared with 30 age-matched normal subjects. The thickness of the ganglion cell complex (GCC), retinal nerve fiber layer (RNFL), and the choroid and foveal loss volume (FLV) were measured by means of optical coherence tomography (OCT). Retrobulbar blood velocities (Color Doppler Imaging), corneal compensated intraocular pressure (IOPcc), and corneal hysteresis (CH) were also evaluated. Mean ocular perfusion pressure (MOPP) was calculated by measuring IOP and mean arterial blood pressure as MOPP = ([2/3 diastolic BP + 1/3 systolic BP] × 2/3-IOP). The value of each diagnostic indicator (z-value) was calculated using the Wilcoxon-Mann-Whitney test and the area under the receiver operating characteristic curve (AUC).

RESULTS: The following indicators had the largest AUC and diagnostic value (z-value): mean blood flow velocity in the vortex veins (AUC 1.0; z-value 5.35) and central retinal vein (0.85; 3.74), diastolic blood flow velocity in the central retinal artery (0.73; 2.74) and lateral short posterior ciliary arteries (0.71; 2.53), IOPcc (0.74; -2.9), CH (0.69; 2.24), CT (0.69; -2.28), GCC (0.67; 2.05), and FLV (0.66; -1.86) to discriminate pre-perimetric glaucoma from healthy subjects.

CONCLUSIONS: Interestingly, ocular hemodynamic parameters performed better than structural parameters in detecting early glaucoma. This highlights the potential of techniques to measure ocular blood flow in glaucoma diagnostics independently of the question whether perfusion abnormalities are a cause or a consequence of the disease.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты