MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ceo.12777

Медицинская библиотека · Clinical & experimental ophthalmology · 2016

Comparison between intraocular pressure spikes with water loading and postural change.

Chong Calum Wk, Wang Sarah B, Jain Neeranjali S, Bank Cassandra S, Singh Ravjit, Bank Allan, Francis Ian C, Agar Ashish

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the agreement between peak intraocular pressures measured through the water drinking test and the supine test, in patients with primary open angle glaucoma.

DESIGN

Consecutive, prospective, blinded.

PARTICIPANTS

Twenty-one patients from the Glaucoma Unit, Prince of Wales Hospital, Sydney, Australia.

METHODS

For the supine test, intraocular pressure was recorded immediately after the patient had lain down and at 20 and 40 min. At the second evaluation, intraocular pressure was measured in each patient after drinking 10 mL/kg body weight of water for the water drinking test. Again, all patients had their intraocular pressure measured at 20 and 40 min (t = 20 and t = 40, respectively). Patients were excluded from the study if they had pre-existing cardiac, renal or pulmonary complications or had concurrent ocular disease or an anatomical abnormality (including angle recession, peripheral anterior synechiae and developmental anomalies of the angle) that may have influenced intraocular pressure.

MAIN OUTCOME MEASURE: Bland-Altman analysis.

RESULTS

Bland-Altman analysis indicated an overall excellent agreement in terms of mean difference between methods (1.0, -1.0 and -0.90 mmHg, at 0, 20 and 40 min, respectively). Further, with the exception of t = 40, all measured time points had 95% confidence intervals within 6.5 mmHg of their mean difference on the Bland-Altman plot.

CONCLUSIONS

There was close agreement between the intraocular pressure values of the supine test and water drinking test. However, as the water drinking test may be uncomfortable and potentially hazardous, there is potential that the supine test may be a safer and more comfortable alternative.

Для цитирования: Chong Calum Wk, Wang Sarah B, Jain Neeranjali S, Bank Cassandra S, Singh Ravjit, Bank Allan, Francis Ian C, Agar Ashish. Comparison between intraocular pressure spikes with water loading and postural change.. Clinical & experimental ophthalmology. 2016. DOI: 10.1111/ceo.12777.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.