Acta ophthalmologica · 2016
The prognostic value of retinal vessel analysis in primary open-angle glaucoma.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Waldmann Nicolas Philipp, Kochkorov Asan, Polunina Anna, Orgül Selim, Gugleta Konstantin
Аннотация
PURPOSE: To analyse a prognostic value of initial retinal vessel flicker response for the 3-year development of functional (visual field) and morphological (nerve fibre layer thickness) damage progression in primary open-angle glaucoma patients.
PATIENTS AND METHODS: Initially, 70 patients were recruited, and flicker response was measured by standardized procedure with the retinal vessel analyser (RVA). Ocular coherence tomography of retinal nerve fibre layer (OCT RNFL) and a visual field testing were performed at beginning and every 6 months for 3 years; 56 patients completed the study.
RESULTS: No correlation was found between the progression of visual field (VF) mean defect and retinal nerve fibre layer (RNFL) thinning over 3 years on one and the maximal flicker reaction in arteries and veins on the other side (all p > 0.1). However, the calculated difference of examined parameters in the superior versus inferior retinal halves correlated significantly between the RNFL thinning and the initial maximal flicker response for arteries (p = 0.01) and veins (p = 0.003).
CONCLUSION: This longitudinal study did not find a general correlation between initial retinal vessel response to flicker light and the glaucoma damage progression measured by OCT and VF, hence limiting the relevance of the RVA device as a predictor of future glaucomatous damage.
PATIENTS AND METHODS: Initially, 70 patients were recruited, and flicker response was measured by standardized procedure with the retinal vessel analyser (RVA). Ocular coherence tomography of retinal nerve fibre layer (OCT RNFL) and a visual field testing were performed at beginning and every 6 months for 3 years; 56 patients completed the study.
RESULTS: No correlation was found between the progression of visual field (VF) mean defect and retinal nerve fibre layer (RNFL) thinning over 3 years on one and the maximal flicker reaction in arteries and veins on the other side (all p > 0.1). However, the calculated difference of examined parameters in the superior versus inferior retinal halves correlated significantly between the RNFL thinning and the initial maximal flicker response for arteries (p = 0.01) and veins (p = 0.003).
CONCLUSION: This longitudinal study did not find a general correlation between initial retinal vessel response to flicker light and the glaucoma damage progression measured by OCT and VF, hence limiting the relevance of the RVA device as a predictor of future glaucomatous damage.
Предметные рубрики MeSH
AgedDiagnostic Techniques, OphthalmologicalFemaleFollow-Up StudiesGlaucoma, Open-AngleHumansIntraocular PressureMaleMiddle AgedNerve FibersPhotic StimulationPrognosisProspective StudiesRetinal Ganglion CellsRetinal VesselsTomography, Optical CoherenceTonometry, OcularVision DisordersVisual Field TestsVisual Fields