MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vop.12165

Медицинская библиотека · Veterinary ophthalmology · 2014

Schirmer tear test I and rebound tonometry findings in healthy calves.

Tofflemire Kyle L, Whitley Elizabeth M, Gould Stacie A, Dewell Renee D, Allbaugh Rachel A, Ben-Shlomo Gil, O'Connor Annette M, David Whitley R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To describe Schirmer tear test I and rebound tonometry findings in healthy bovine calves.

ANIMALS STUDIED: Thirty-three clinically normal dairy breed calves of mean (SD) 11 (1.1) weeks (range, 9.3-13.3 weeks) of age were evaluated.

PROCEDURES: A Schirmer tear test I was performed on each eye followed by tonometry, using a TonoVet(®) without topical anesthesia. We report means (SD) and statistical analysis of data for each assay.

RESULTS

For both Schirmer tear test (STT) I and tonometry, significant differences were not found between fellow eyes (P = 0.1536 and P = 0.83, respectively). The mean (SD) STT I value of all eyes was 20.4 (5.0) mm/min (range, 9-34 mm/min) while the mean (SD) intraocular pressure (IOP) value of all eyes was 15.2 (5.2) mmHg (range, 7-25 mmHg).

CONCLUSIONS

This study reports normal data for the STT I and rebound tonometry in calves. This data may be useful in complete ophthalmic examinations of cattle, guiding diagnosis of glaucoma, uveitis, and keratoconjunctivitis sicca. However, results of these diagnostic modalities must be interpreted in light of clinical signs, given the wide range of normal values obtained in this study.

Для цитирования: Tofflemire Kyle L, Whitley Elizabeth M, Gould Stacie A, Dewell Renee D, Allbaugh Rachel A, Ben-Shlomo Gil, O'Connor Annette M, David Whitley R. Schirmer tear test I and rebound tonometry findings in healthy calves.. Veterinary ophthalmology. 2014. DOI: 10.1111/vop.12165.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.