MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721241267028

Медицинская библиотека · European journal of ophthalmology · 2024

Tilt and decentration of the crystalline lens in ultra-high myopia with cataract and its influencing factors: A study based on CASIA2'.

Zhao Hui-Ying, Zhang Jing-Shang, Li Meng, Chen Dong-Jun, Yang Xi, Wan Xiu-Hua

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aims to examine the characteristics and influencing factors of crystalline lens tilt and decentration in ultra-high myopic cataract patients, as measured by the CASIA2.

METHODS AND ANALYSIS: 60 eyes scheduled for cataract surgery with an axial length (AL) ≥ 28 mm were included. The IOLMaster700 was utilized to measure AL and the white-to-white (WTW) distance. The CASIA2 was employed to measure front curvature radius (FCR), crystalline lens tilt, and crystalline lens decentration. The relationships between lens tilt, decentration, and related factors were evaluated.

RESULTS

The degree of lens tilt was 4.62 ± 2.44°, and the decentration was 0.20 (Q1 0.13, Q3 0.28) mm. Among the 60 eyes, 11 (18.3%) had a tilt ≥7°, and 6 (10%) had a decentratiolens tilt ≥7° (P = 0.038, P = 0.018). Eyes with AL >30.00 mm and FCR <8.45 mm had a higher degree of lens tilt. Additionally, a tilt ≥7° was associated with a greater decentration (P = 0.032), n.

CONCLUSION

Preoperative crystalline lenses in eyes with ultra-high myopia and cataract exhibit certain degrees of tilt and decentration. An AL >30 mm is a risk factor for a lens tilt ≥7° and an decentration ≥0.4 mm. An FCR <8.45 mm is a risk factor for increased lens tilt, and a tilt ≥7° is a risk factor for increased lens decentrati ≥ 0.4 mm. An increase in AL and FCR <8.45 mm were risk factors for a and eyes with AL >30.00 mm had a higher degree of decentration (P = 0.005).

Для цитирования: Zhao Hui-Ying, Zhang Jing-Shang, Li Meng, Chen Dong-Jun, Yang Xi, Wan Xiu-Hua. Tilt and decentration of the crystalline lens in ultra-high myopia with cataract and its influencing factors: A study based on CASIA2'.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241267028.