m+Medelevator.RU
← Поиск публикаций
International journal of ophthalmology · 2024

Early changes in corneal densitometry after FS-LASIK combined with accelerated corneal cross-linking for correction of high myopia.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Qing-Bao, Bi Hong-Sheng, Wang Xiao-Fan, Fan Hua, Li Li, Ji Peng

Аннотация

AIM: To observe the effects of femtosecond laser-assisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking (FS-LASIK Xtra) on corneal densitometry after correcting for high myopia.

METHODS: In this prospectively study, 130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia. Their right eyes were selected for inclusion in the study, of which 65 cases of 65 eyes in the FS-LASIK group, 65 patients with 65 eyes in the FS-LASIK Xtra group. Patients were evaluated for corneal densitometry at 1, 3, and 6mo postoperatively using Pentacam Scheimpflug imaging.

RESULTS: Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant (P>0.05). Layer-by-layer analysis revealed statistically significant differences in the anterior (120 µm), central, and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively (all P<0.05), the FS-LASIK Xtra group is higher than that of the FS-LASIK group. Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0-2, 2-6, and 6-10 mm (both P<0.05); At 3mo postoperatively, the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0-2 and 2-6 mm (P<0.05). At 6mo postoperatively, there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges (all P>0.05).

CONCLUSION: There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia. However, the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery, with the most significant changes observed in the superficial central zone.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты