Circulation journal : official journal of the Japanese Circulation Society · 2006
Is circumferential pulmonary vein isolation preferable to stepwise segmental pulmonary vein isolation for patients with paroxysmal atrial fibrillation?
Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Xingpeng, Long Deyong, Dong Jianzeng, Hu Fuli, Yu Ronghui, Tang Ribo, Fang Dongping, Hao Peng, Lu Chunshan, Liu Xiaoqing, He Xiaokui, Liu Xiaohui, Ma Changsheng
Аннотация
BACKGROUND: Stepwise segmental pulmonary vein isolation (SPVI) and circumferential pulmonary vein isolation (CPVI) have been developed to treat patients with atrial fibrillation (AF), but the preferable approach for paroxysmal AF (PAF) has not been established.
METHODS AND RESULTS: One hundred and ten patients with symptomatic PAF were randomized into a stepwise SPVI group (n=55) or CPVI group (n=55). Systemic SPVI combined with left atrial linear ablation tailored by inducibility of AF was performed in the stepwise SPVI group. Circumferential linear ablation around the left and right-sided pulmonary veins (PVs) guided by 3-dimensional electroanatomic mapping was performed in the CPVI group. The endpoints of ablation are non-induciblity of AF in the stepwise SPVI group and continuity of circular lesions combined with PV isolation in the CPVI group. After the initial procedures, atrial tachyarrhythmis (ATa) recurred within the first 3 months in 23 of the 55 patients (41.8%) who underwent stepwise SPVI and in 20 of the 55 patients (36.4%) who had CPVI (p=0.69). Repeat procedures were performed in 7 patients from the stepwise SPVI group and 5 from the CPVI group (p=0.76). During the 3-9 months after the last procedure, 46 patients (83.6%) from the CPVI group and 43 (78.2%) from the stepwise SPVI group did not have symptomatic ATa while not taking anti-arrhythmic drugs (p=0.63). Severe subcutaneous hematoma or PV stenosis occurred in 3 patients.
CONCLUSIONS: The efficacy of stepwise SPVI is comparable to that of CPVI for patients with PAF.
METHODS AND RESULTS: One hundred and ten patients with symptomatic PAF were randomized into a stepwise SPVI group (n=55) or CPVI group (n=55). Systemic SPVI combined with left atrial linear ablation tailored by inducibility of AF was performed in the stepwise SPVI group. Circumferential linear ablation around the left and right-sided pulmonary veins (PVs) guided by 3-dimensional electroanatomic mapping was performed in the CPVI group. The endpoints of ablation are non-induciblity of AF in the stepwise SPVI group and continuity of circular lesions combined with PV isolation in the CPVI group. After the initial procedures, atrial tachyarrhythmis (ATa) recurred within the first 3 months in 23 of the 55 patients (41.8%) who underwent stepwise SPVI and in 20 of the 55 patients (36.4%) who had CPVI (p=0.69). Repeat procedures were performed in 7 patients from the stepwise SPVI group and 5 from the CPVI group (p=0.76). During the 3-9 months after the last procedure, 46 patients (83.6%) from the CPVI group and 43 (78.2%) from the stepwise SPVI group did not have symptomatic ATa while not taking anti-arrhythmic drugs (p=0.63). Severe subcutaneous hematoma or PV stenosis occurred in 3 patients.
CONCLUSIONS: The efficacy of stepwise SPVI is comparable to that of CPVI for patients with PAF.