Purpose: To evaluate the safety and efficacy of the transepithelial photorefractive keratectomy (TransPRK) performed using smart pulse technology (SPT) in myopic eyes with refractive error ranging from -5.25 D to -9.75 D.

Methods

This retrospective study evaluated the outcomes of SPT-assisted TransPRK in 150 eyes performed using a 1050 Hz AMARIS excimer laser.

Results

At 6 months postoperative, 98% of eyes achieved uncorrected distance visual acuity (UDVA) of 20/25 or better, and postoperative UDVA within one line of preoperative corrected distance visual acuity (CDVA). No eyes lost any line of CDVA. Residual spherical equivalent refraction and cylinder within ±0.50 D of intended correction were achieved in 72% and 67% of eyes, respectively. Ninety-seven percent of eyes reported no halos and glare.

Conclusions

TransPRK using a 1050 Hz excimer laser with SPT showed excellent predictability, safety, and efficacy for moderate to high myopia correction.

Для цитирования: Ho Tony. Clinical Outcomes of Transepithelial Photorefractive Keratectomy Performed with Smart Pulse Technology for the Correction of Moderate to High Myopia.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13113058.