DOI 10.3928/1081597x-20240422-04

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2024

The Long-term Visual Quality and Rotational Stability After ICL/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years.

Ye Yuhao, Xu Yijia, Zhang Zhe, Niu Lingling, Shi Wanru, Wang Xiaoying, Zhou Xingtao, Zhao Jing

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the long-term visual quality and rotational stability after the implantation of Implantable Collamer Lens (ICL) and toric ICL (TICL) (STAAR Surgical) in patients with myopia older than 40 years.

METHODS

This study included 82 eyes of 41 patients older than 40 years with myopia who underwent ICL/TICL V4c implantation. The refraction sphere, refraction cylinder, spherical equivalent (SE), uncorrected and corrected distance visual acuity, and anterior segmental parameters were measured preoperatively and at the 1-month, 3-month, and last follow-up visits at 33 to 58 months postoperatively (mean follow-up: 42.56 ± 7.17 months). Wavefront aberrations and TICL rotation were measured using OPD-Scan III (Nidek Co Ltd) at the last follow-up visit.

RESULTS

At the last follow-up visit, the overall safety and efficacy index were 1.22 ± 0.26 and 0.88 ± 0.34, respectively, without significant differences between the ICL and TICL groups. Postoperative refraction cylinder was -0.95 ± 0.64 and -0.71 ± 0.54 diopters in the ICL and TICL groups, respectively. The average vault was 467.44 ± 231.98 µm. The average TICL rotation was 5.45 ± 6.61 degrees, positively correlated with the preoperative anterior chamber volume (R2 = 0.1118, P = .026) and clockwise TICL alignment degree (R2 = 0.3110, P = .007) and negatively correlated with the 1-month vault (R2 = 0.1218, P = .008). There were no significant differences in the total, corneal, or internal aberrations and modulation transfer function AreaRatio between the ICL and TICL groups.

CONCLUSIONS

Both ICL and TICL presented satisfactory long-term safety, efficacy, and visual quality in patients older than 40 years. Postoperative TICL spontaneous rotation was within the manageable range in the long term. [J Refract Surg. 2024;40(6):e381-e391.].

Для цитирования: Ye Yuhao, Xu Yijia, Zhang Zhe, Niu Lingling, Shi Wanru, Wang Xiaoying, Zhou Xingtao, Zhao Jing. The Long-term Visual Quality and Rotational Stability After ICL/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2024. DOI: 10.3928/1081597x-20240422-04.