Biological ultrathin amniotic membrane flap to close refractory macular holes associated with high myopia.

Fan Yuanyuan, Wang Jiagui, Lei Jie, Ji Jiangdong, Xie Ping, Hu Zizhong

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To propose an ultrathin biological amniotic membrane (btAM) thinner than 10 μm as the graft to treat highly myopic macular holes (MH).

METHODS

This pilot study included 14 patients affected by refractory macular holes associated with high myopia. btAM was used as a bandage covering the holes. The best-corrected visual acuity (BCVA), fundus photography, and optical coherence tomography (OCT) before and after surgery were compared.

RESULTS

The mean MH size was 865.93 ± 371.72 μm and all the MHs achieved anatomical closure. The btAM located centrally and fully on MHs from fundus photography yet no obvious visual masking was complained. The average BCVA 1 month, 3, and 6 months after surgery were 0.95 ± 0.24, 0.92 ± 0.23, 0.92 ± 0.23 logMAR, respectively, improved significantly compared to pre-operative BCVA (1.24 ± 0.42 logMAR, all P < 0.05). Ten out of 14 (71.4%) exhibited 2C closure patterns (formally closed and no bare RPE) on OCT.

CONCLUSION

The btAM thinner showed a favorable anatomical success with less risk of parafoveal atrophy or iatrogenic injuries and shortened the dissolving time.

Для цитирования: Fan Yuanyuan, Wang Jiagui, Lei Jie, Ji Jiangdong, Xie Ping, Hu Zizhong. Biological ultrathin amniotic membrane flap to close refractory macular holes associated with high myopia.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2024. DOI: 10.1007/s00417-024-06509-7.