MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-018-0955-3

Медицинская библиотека · BMC ophthalmology · 2018

Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial.

Jung Na Yeon, Lim Dong Hui, Hwang Sung Soon, Hyun Joo, Chung Tae-Young

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

To compare the clinical outcome of Precizon toric intraocular lens (IOL) (Ophtec Inc.) to that of Tecnis toric IOL (Abbott Medical Optics Inc.).

METHODS

This randomized comparative study included 40 eyes (Precizon, 20 eyes; Tecnis, 20 eyes) of 40 patients with visually significant cataract and corneal astigmatism who underwent cataract surgery. Changes in uncorrected distant visual acuity (UCDVA), best corrected distant visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), refraction, residual astigmatism, rotation of the IOL axis, and higher order aberrations at 3 months postoperatively were evaluated. Vector analysis was performed using the Alpins method.

RESULTS

Both groups showed significant reduction in refractive astigmatism after the surgery (Precizon: - 1.06 ± 0.94 Diopter (D) to - 0.31 ± 0.29 D, p = 0.042; Tecnis: - 1.83 ± 1.29 D to - 0.41 ± 0.33 D, p = 0.015). There was no significant (p > 0.05) difference in postoperative UCDVA, BCDVA, or residual astigmatism between the two groups, although a tendency of better UCIVA was observed in the Precizon group. Vector analysis parameters showed no statistically significant difference beween groups(P > 0.05). Significant difference in rotation of toric IOL axis was found between the two groups (Precizon: 1.50° ± 0.84, Tecnis: 2.56° ± 0.68, p = 0.010). Spherical aberration in the Precizon group was significantly (p = 0.005) lower than that in the Tecnis group.

CONCLUSIONS

The Precizon toric IOL group had better rotational stability at 3-month postoperatively. Both Precizon toric IOL and Tecnis toric IOL could be effectively used by cataract surgeons to correct preexisting corneal astigmatism through cataract surgery.

TRIAL REGISTRATION: http://clinicaltrials.gov , NCT03085901 , retrospectively registered on 21 March 2017.

Для цитирования: Jung Na Yeon, Lim Dong Hui, Hwang Sung Soon, Hyun Joo, Chung Tae-Young. Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial.. BMC ophthalmology. 2018. DOI: 10.1186/s12886-018-0955-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.