MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000366136

Медицинская библиотека · Respiration; international review of thoracic diseases · 2014

Suitability of small bronchoscopic tumour specimens for lung cancer genotyping.

Dooms Christophe, Vliegen Liesbet, Vander Borght Sara, Yserbyt Jonas, Hantson Inge, Verbeken Eric, Wauters Els, Nackaerts Kristiaan, Ninane Vincent, Vansteenkiste Johan, Vandenberghe Peter

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Biomarker-driven clinical trials in advanced non-small cell lung cancer (NSCLC) usually accept biopsy specimens only, as cytology specimens are supposed to be more challenging due to low neoplastic cell content and suboptimal DNA quantity.

OBJECTIVES

We aimed to evaluate 2 aspects of bronchoscopic biopsy and cytology specimens: (1) the proportion of neoplastic cells and quantity of DNA extracted, and (2) the detection limit of the Scorpion amplification refractory mutation system on endoscopic samples obtained in daily clinical practice.

METHODS

We screened 679 patients with advanced-stage NSCLC for the presence of an activating EGFR mutation according to the guidelines of the European Society of Medical Oncology. Their diagnostic tumour tissue samples were characterized. A dilution experiment was performed to determine the minimal proportion of neoplastic cells for a reliable test result.

RESULTS

Surgical biopsies, bronchoscopic forceps biopsy samples and needle aspiration cytology specimens exhibited a median tumour cell proportion of 70 versus 30 versus 20% and a DNA quantity of 2,500 versus 1,610 versus 1,440 ng, respectively. The overall EGFR mutation rate was 11%, with no differences between different sample types. Dilution experiments showed that the detection limit depends on the type of mutation. A neoplastic cell content of at least 10 and 25% for exon 19 deletions and exon 21 L858R point mutation, respectively, was required for a true negative result.

CONCLUSIONS

Bronchoscopic forceps biopsy and needle aspiration cytology specimens are suitable for accurate EGFR mutation analysis using single-gene quantitative real-time polymerase chain reaction. Technologies with a better analytical sensitivity are evolving and should consider these endoscopic tumour specimens.

Для цитирования: Dooms Christophe, Vliegen Liesbet, Vander Borght Sara, Yserbyt Jonas, Hantson Inge, Verbeken Eric, Wauters Els, Nackaerts Kristiaan, Ninane Vincent, Vansteenkiste Johan, Vandenberghe Peter. Suitability of small bronchoscopic tumour specimens for lung cancer genotyping.. Respiration; international review of thoracic diseases. 2014. DOI: 10.1159/000366136.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.