MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.118.006989

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2019

Multicenter Study of the Validity of Additional Freeze Cycles for Cryoballoon Ablation in Patients With Paroxysmal Atrial Fibrillation: The AD-Balloon Study.

Miyamoto Koji, Doi Atsushi, Hasegawa Kanae, Morita Yoshiaki, Mishima Tsuyoshi, Suzuki Ippei, Kaseno Kenichi, Nakajima Kenzaburo, Kataoka Naoya, Kamakura Tsukasa, Wada Mitsuru, Yamagata Kenichiro, Ishibashi Kohei, Inoue Yuko Y, Nagase Satoshi, Noda Takashi, Aiba Takeshi, Asakura Masanori, Izumi Chisato, Noguchi Teruo, Tada Hiroshi, Takagi Masahiko, Yasuda Satoshi, Kusano Kengo F

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) is a cornerstone of catheter ablation in patients with paroxysmal atrial fibrillation, and balloon-based ablation has been recently performed worldwide. The second-generation cryoballoon (CB2) ablation has proven to be highly effective in achieving freedom from paroxysmal atrial fibrillation. However, there are some debatable questions, including the ideal number of freeze cycles.

METHODS

The AD-Balloon study (Multicenter Study of the Validity of Additional Freeze Cycles for Cryoballoon Ablation) was designed as a prospective, multicenter, and randomized clinical trial for investigation of the optimal strategy of freeze cycles for the CB2 ablation. One hundred and ten consecutive patients (aged 64±11 years) were randomly assigned to 2 groups after achieving a PVI by the CB2 ablation: 3-minute freeze cycles were added to each pulmonary vein (AD group: n=55) or not (non-AD group: n=55). Delayed-enhancement magnetic resonance imaging was also performed 1 to 2 months after the PVI to assess the ablation lesions.

RESULTS

The patient characteristics did not differ between the 2 groups. A complete PVI was achieved in all patients. The total number of freeze cycles and durations for all pulmonary veins were significantly shorter in the non-AD group than in the AD group (5.7±1.6 versus 9.1±1.6 cycles, P<0.0001, and 932±244 versus 1483±252 seconds, P<0.0001). The cumulative freedom from any atrial tachyarrhythmia at 1 year was 87.3% in the AD group and 89.1% in the non-AD group (log-rank test P=0.78). There was no significant difference in the frequency of gaps on the PVI lines in the delayed-enhancement magnetic resonance imaging (46% in the AD group versus 36% in the non-AD group; P=0.38).

CONCLUSIONS

No benefit was found in the patients receiving additional 3-minute freeze cycles after the complete PVI with the CB2 ablation, suggesting that an insurance freeze after achieving a PVI with the CB2 may be unnecessary and time consuming.

Для цитирования: Miyamoto Koji, Doi Atsushi, Hasegawa Kanae, Morita Yoshiaki, Mishima Tsuyoshi, Suzuki Ippei, Kaseno Kenichi, Nakajima Kenzaburo, Kataoka Naoya, Kamakura Tsukasa, Wada Mitsuru, Yamagata Kenichiro, Ishibashi Kohei, Inoue Yuko Y, Nagase Satoshi, Noda Takashi, Aiba Takeshi, Asakura Masanori, Izumi Chisato, Noguchi Teruo, Tada Hiroshi, Takagi Masahiko, Yasuda Satoshi, Kusano Kengo F. Multicenter Study of the Validity of Additional Freeze Cycles for Cryoballoon Ablation in Patients With Paroxysmal Atrial Fibrillation: The AD-Balloon Study.. Circulation. Arrhythmia and electrophysiology. 2019. DOI: 10.1161/circep.118.006989.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.