Repeat ablation for paroxysmal atrial fibrillation - Does adenosine play a role in predicting pulmonary vein reconnection patterns?

Kottmaier M, Bourier F, Wünscher S, Kornmayer M, Semmler V, Lengauer S, Telishevska M, Koch-Büttner K, Risse E, Brooks S, Hessling G, Deisenhofer I, Reents T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein (PV) reconduction after PV isolation (PVI) unmasked by adenosine is associated with a higher risk for paroxysmal atrial fibrillation (PAF) recurrence. It is unknown if the reconnected PVs after adenosine testing and immediate re-ablation can predict reconnection and reconnection patterns of PVs at repeat procedures. We assessed reconnection of PVs with and without dormant-conduction (DC) during the first and the repeat procedure.

METHODS

We included 67 patients undergoing PVI for PAF and a second procedure for PAF recurrence. DC during adenosine administration at first procedure was seen in 31 patients (46%). 264 PVs were tested with adenosine; DC was found in 48 PVs (18%) and re-ablated during first procedure. During the second procedure, all PVs where checked for reconnection.

RESULTS

Fifty-eight patients (87%) showed PV reconnection during the second procedure. Reconnection was found in 152/264 PVs (58%). Of 216 PVs without reconnection during adenosine testing at the first ablation, 116 PVs (53.7%) showed reconnection at the repeat procedure. Overall, 14.9% of patients showed the same PV reconnection pattern in the first and second procedure, expected statistical probability of encountering the same reconnection pattern was only 6.6%(p = 0.012).

CONCLUSIONS

In repeat procedures PVs showed significantly more often the same reconnection pattern as during first procedure than statistically expected. More than 50% of initial isolated PVs without reconnection during adenosine testing showed a reconnection during repeat ablation. Techniques to detect susceptibility for PV re-connection like prolonged waiting-period should be applied. Elimination of DC should be expanded from segmental to circumferential re-isolation or vaster RF application.

Для цитирования: Kottmaier M, Bourier F, Wünscher S, Kornmayer M, Semmler V, Lengauer S, Telishevska M, Koch-Büttner K, Risse E, Brooks S, Hessling G, Deisenhofer I, Reents T. Repeat ablation for paroxysmal atrial fibrillation - Does adenosine play a role in predicting pulmonary vein reconnection patterns?. Indian pacing and electrophysiology journal. 2018. DOI: 10.1016/j.ipej.2018.09.002.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.