Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2019
Comparison of a high throughput day case atrial fibrillation ablation service in a local hospital with standard regional tertiary cardiac centre care.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Opel Aaisha, Mansell Josephine, Butler Alison, Schwartz Rhona, Fannon Michael, Finlay Malcolm, Hunter Ross J, Schilling Richard J
Аннотация
AIMS: We investigated safety and efficacy of a high throughput atrial fibrillation (AF) ablation service within a local non-cardiac centre compared with matched patients at the regional tertiary cardiac centre.
METHODS AND RESULTS: Patients were consented in clinic and pre-assessed by clerical staff. Locally, other than physicians, staff had no experience of ablation and were trained with simulations. Pulmonary vein isolation (PVI) was performed with conscious sedation, on uninterrupted anticoagulation for at least 4 weeks. No transoesophageal echocardiogram (TOE) was performed. A 28 mm Arctic Front Advance Cryoballoon was used. A 20 mm Achieve wire demonstrated PVI on a portable laptop-based EP recording system. Phrenic nerve function was monitored during right PVI. Finally, a transthoracic echocardiogram excluded a pericardial effusion. A Femostop was applied. Two hundred and seventy-six patients were matched. Average age was 61 ± 0.7 years, 39% female. CHA2DS2 VASc score varied from 0 to 7. Procedure time was significantly shorter at the local hospital (63.5 ± 1.1 vs. 101.7 ± 2.9 min, P < 0.0001). Fluoroscopy time (5.5 ± 0.2 vs. 12.6 ± 0.6 min, P < 0.0001) and fluoroscopy dose were lower (17.2 ± 2.1 vs. 97.6 ± 14.6 mGy, P < 0.0001). Successful PVI was achieved in all. The complication rate was low (5.4% vs. 6.3%, P = not significant). Four (1.4%) patients were not day case discharges. At 3 month follow-up, 54.3% had complete resolution, and 26.1% had improvement of symptoms. A total of 16.6% patients requested repeat procedures for ongoing symptoms.
CONCLUSION: In experienced hands, cryoballoon for paroxysmal AF is delivered safely and effectively in a local centre. Outcomes remain excellent. These short, day case procedures allow utilization of non-cardiac centres. The service provides a model to meet increasing demands.
METHODS AND RESULTS: Patients were consented in clinic and pre-assessed by clerical staff. Locally, other than physicians, staff had no experience of ablation and were trained with simulations. Pulmonary vein isolation (PVI) was performed with conscious sedation, on uninterrupted anticoagulation for at least 4 weeks. No transoesophageal echocardiogram (TOE) was performed. A 28 mm Arctic Front Advance Cryoballoon was used. A 20 mm Achieve wire demonstrated PVI on a portable laptop-based EP recording system. Phrenic nerve function was monitored during right PVI. Finally, a transthoracic echocardiogram excluded a pericardial effusion. A Femostop was applied. Two hundred and seventy-six patients were matched. Average age was 61 ± 0.7 years, 39% female. CHA2DS2 VASc score varied from 0 to 7. Procedure time was significantly shorter at the local hospital (63.5 ± 1.1 vs. 101.7 ± 2.9 min, P < 0.0001). Fluoroscopy time (5.5 ± 0.2 vs. 12.6 ± 0.6 min, P < 0.0001) and fluoroscopy dose were lower (17.2 ± 2.1 vs. 97.6 ± 14.6 mGy, P < 0.0001). Successful PVI was achieved in all. The complication rate was low (5.4% vs. 6.3%, P = not significant). Four (1.4%) patients were not day case discharges. At 3 month follow-up, 54.3% had complete resolution, and 26.1% had improvement of symptoms. A total of 16.6% patients requested repeat procedures for ongoing symptoms.
CONCLUSION: In experienced hands, cryoballoon for paroxysmal AF is delivered safely and effectively in a local centre. Outcomes remain excellent. These short, day case procedures allow utilization of non-cardiac centres. The service provides a model to meet increasing demands.
Предметные рубрики MeSH
Ambulatory Surgical ProceduresAnticoagulantsAtrial FibrillationProcedural SedationCryosurgeryFemaleHealth Services Needs and DemandHospitals, High-VolumeHospitals, Low-VolumeHumansLength of StayMaleMedical AuditMiddle AgedOperative TimePatient DischargePatient SafetyPostoperative ComplicationsProspective StudiesPulmonary VeinsRecurrenceReoperationRisk AssessmentRisk FactorsTertiary Care CentersTime FactorsTreatment Outcome