Reproducibility of laser in situ keratomileusis flap thickness using a new multifunctional femtosecond laser platform and correlation with clinical preoperative measurements.

Colombo-Barboza Marcello N, Colombo-Barboza Guilherme N, Colombo-Barboza Luiz Roberto, Matuoka Mateus L, Neto Adamo Lui, de Freitas Denise

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the reproducibility of laser in situ keratomileusis (LASIK) flap thickness (target 120 μm) using the multifunctional femtosecond laser (Lensx) and correlate postsurgical measurements with preoperative factors.

SETTING

Hospital Oftalmológico Visão Laser, Santos, São Paulo, Brazil.

DESIGN

Prospective case series.

METHODS

Patients with stable refraction for over a year were evaluated. Patients who submitted to refractive surgery with -1.25 to -6.00 diopters (D), with or without astigmatism up to -4.00 D, and corneal curvature of 40.00 to 47.00 D were included. At 100 days postoperatively, an independent examiner performed 4 high-resolution tomographic sections of the cornea for each eye at 45- to 225-degree, 90- to 270-degree, 135- to 315-degree, and 0- to 180-degree meridians. Two masked experienced observers analyzed each section using measuring points located at the center of the cornea (0.0 mm), 2.0 mm to the left and to the right of the center, and 4.0 mm to the left and to the right of the center.

RESULTS

The study comprised 33 patients (63 eyes), aged 21 to 50 years. A significant difference from the target flap thickness (120 μm) was found in 2 of 20 measurements; however, the actual difference was approximately 2.2 μm. Interrater reliability was excellent (ICC > 0.75), with an interrater bias close to 0. Clinical measurements were not predictive of the set of 20 postoperative measurements.

CONCLUSION

Reproducibility of the multifunctional femtosecond laser was good for LASIK flap creation and no predictive correlation was found with preoperative clinical factors.

Для цитирования: Colombo-Barboza Marcello N, Colombo-Barboza Guilherme N, Colombo-Barboza Luiz Roberto, Matuoka Mateus L, Neto Adamo Lui, de Freitas Denise. Reproducibility of laser in situ keratomileusis flap thickness using a new multifunctional femtosecond laser platform and correlation with clinical preoperative measurements.. Journal of cataract and refractive surgery. 2018. DOI: 10.1016/j.jcrs.2018.05.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.