Lyan Evgeny, Tsyganov Alexey, Abdrahmanov Ayan, Morozov Alexander, Bakytzhanuly Abay, Tursunbekov Azat, Nuralinov Omirbek, Mironovich Sergey, Klukvin Alexander, Marinin Valery, Tilz Roland Richard, Sawan Noureddin

Аннотация

AIMS: Radiofrequency catheter ablation of atrial fibrillation (AF) is one of the most complex ablation procedures. Both patients and operators are exposed to scattered radiation. This study evaluated the safety and efficacy of intracardiac echo (ICE)-guided pulmonary vein isolation (PVI) without fluoroscopy.

METHODS: We retrospectively analyzed the data of 481 consecutive patients with paroxysmal AF undergoing radiofrequency PVI with the CARTO 3 system (Biosense Webster, Diamond Bar, CA, USA). ICE-guided PVI without fluoroscopy and without CT/MRI integration (Nonfluoro group) was performed for 245 patients, and conventional fluoroscopy-guided PVI (Fluoro group) was performed for 236 patients. The primary safety endpoint was the incidence of major adverse events. The primary efficacy endpoint was freedom from AF during follow-up. Secondary endpoints included procedure duration, fluoroscopy duration, and acute PVI rate.

RESULTS: Mean procedure times between groups were similar (108.8 ± 18.2 minutes in the Non-fluoro group vs 113.6 ± 26.8 minutes in the Fluoro group; P  =  not significant [NS]). Acute PVI was achieved in all patients, with mean radiofrequency application times of 43.4 ± 7.5 and 44.4 ± 10.7 minutes for the Nonfluoro and Fluoro groups, respectively (P  =  NS). The incidence of cardiac tamponade was 1.2% (3/245 patients) in the Nonfluoro group and 0.8% (2/236 patients) in the Fluoro group (P  =  NS). During 15.2 ± 4.1 months of follow-up, after a single procedure, AF recurrence was documented in 65 of 245 (26.5%) patients and 61 of 236 (25.8%) patients in the Nonfluoro and Fluoro groups, respectively (P  =  NS).

CONCLUSIONS: Nonfluoroscopic ICE-guided catheter ablation of AF without prior cardiac image integration or angiography is feasible and safe. PVI without fluoroscopy did not affect procedure duration or long-term efficacy.