Real-Time Intraocular Pressure Measurements in the Vitreous Chamber of Rabbit Eyes During Small Incision Lenticule Extraction (SMILE).

Cheng Wenbo, Liu Lingjia, Yu Shasha, Jing Yin, Zuo Tong, Cui Tong, Zhang Hui, Ma Jiaonan, Wei Pinghui, Hao Weiting, Lap-Ki Ng Alex, Pak-Man Cheng George, Chi-Pang Woo Victor, Chiu Kin, Wang Yan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate real-time intraocular pressure (IOP) during small incision lenticule extraction (SMILE) in rabbit eyes for myopia correction.

METHODS

During SMILE, real-time IOP was measured in the vitreous cavity of rabbit eyes with an optic fiber pressure sensor (OFPS). Two groups (n = 6 for each) underwent surgery, one group for a -2.00 diopter (D) refractive spherical correction and the other for a -6.00 D correction.

RESULTS

During surgery, the IOP increased once the glass contact attached to the cornea (Pre-suction), and peaked 83.94 mmHg (SD ± 23.87 mmHg) for the -2.00 D group and 89.17 mmHg (SD ± 22.66 mmHg) for the -6.00 D group, both average values were less than 110 mmHg when suction was initiated to fix the glass contact onto the cornea (Suction on). It then fell to 74.81 mmHg (SD ± 20.64 mmHg) and 76.94 mmHg (SD ± 27.43 mmHg), respectively, and remained stable during lenticule creation (Cutting). After suction stopped (Suction off), IOP fell steeply. During lenticule separation/extraction, the change in IOP was 32.26 mmHg (SD ± 2.91 mmHg). Notably, the average duration of elevated IOP during the surgery was 166.05 s (no longer than 3 min).

CONCLUSIONS

The IOP fluctuations in the vitreous cavity using an OFPS in a rabbit model during SMILE showed that real-time IOP significantly was increased during Pre-suction, Suction on, Cutting, Suction off, and lenticule separation/extraction compared to baseline IOP, although, peaked at Suction on. Neither the degree of myopic correction nor central corneal thickness significantly affected these changes in IOP.

Для цитирования: Cheng Wenbo, Liu Lingjia, Yu Shasha, Jing Yin, Zuo Tong, Cui Tong, Zhang Hui, Ma Jiaonan, Wei Pinghui, Hao Weiting, Lap-Ki Ng Alex, Pak-Man Cheng George, Chi-Pang Woo Victor, Chiu Kin, Wang Yan. Real-Time Intraocular Pressure Measurements in the Vitreous Chamber of Rabbit Eyes During Small Incision Lenticule Extraction (SMILE).. Current eye research. 2018. DOI: 10.1080/02713683.2018.1485949.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.