Clinical research in cardiology : official journal of the German Cardiac Society · 2018

Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation.

СтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schaeffer Benjamin, Willems Stephan, Meyer Christian, Lüker Jakob, Akbulak Ruken Ö, Moser Julia, Jularic Mario, Eickholt Christian, Schwarzl Jana M, Gunawardene Melanie, Kuklik Pawel, Sultan Arian, Hoffmann Boris A, Steven Daniel

Аннотация

AIMS: Contact force (CF) catheters provide catheter-tissue contact information to improve outcome of pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (PAF). We evaluated different target-CF values for achievement of the additional endpoint of an unexcitable ablation line.

METHODS: A total of 106 patients undergoing PVI were randomized into three groups (G) (G1: target-CF 15 g, G2: target-CF 10 g, G3: CF concealed from operator). The PVI encircling line was divided into predefined sections. Excitable tissue along the PVI-line identified by high output pacing (10 V, 2 ms) was targeted for further ablation.

RESULTS: Mean average CF was 17.4 ± 4.7 g (G1) vs. 12.3 ± 6.0 g (G2) vs. 11.1 ± 6.5 g (G 3) (p < 0.001). Primary unexcitable ablation lines were found in 38.6, 19.4 and 5.7% (G1, G2, G3 respectively; G1 vs. G2 p < 0.05, G1 vs. G3 p < 0.001, G2 vs. G3 ns). Additional radiofrequency (RF)-energy to achieve unexcitability was lowest in G1 (3.6 ± 3.1 kJ vs. 8.6 ± 7.2 kJ (G2) and 10.4 ± 6.7 (G3), p ≤ 0.001, G2 vs. G3 ns) with accordingly lowest additional RF applications in G1 (3.0 ± 2.6 vs. 7.0 ± 5.4 in G2 and 8.4 ± 4.0 in G3; G1 vs. G2 and G3, p < 0.001, G 2 vs. G 3 ns). Sections along ablation lines with low initial CF were most likely to reveal excitability. Single procedure success was 81.9 vs. 73.5 vs. 71.4% (G 1, 2 and 3, p = 0.6) during 437 ± 254 day follow-up.

CONCLUSION: Higher tip-to-tissue CF during PVI facilitates the achievement of an unexcitable ablation line, requiring less additional RF-energy.