MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s164175

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2018

Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

Titiyal Jeewan S, Kaur Manpreet, Jose Cijin P, Falera Ruchita, Kinkar Ashutosh, Bageshwar Lalit Ms

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality.

PATIENTS AND

METHODS

This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30.

RESULTS

Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05).

CONCLUSION

Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

Для цитирования: Titiyal Jeewan S, Kaur Manpreet, Jose Cijin P, Falera Ruchita, Kinkar Ashutosh, Bageshwar Lalit Ms. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.. Clinical ophthalmology (Auckland, N.Z.). 2018. DOI: 10.2147/opth.s164175.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.