DOI 10.1111/jce.13387

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2017

Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.

Kishima Hideyuki, Mine Takanao, Takahashi Satoshi, Ashida Kenki, Ishihara Masaharu, Masuyama Tohru

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Left atrium (LA) systolic dysfunction is observed in the early stages of atrial fibrillation (AF) prior to LA anatomical change. We investigated whether LA systolic dysfunction predicts recurrent AF after catheter ablation (CA) in patients with paroxysmal AF.

METHODS AND

RESULTS

We studied 106 patients who underwent CA for paroxysmal AF. LA systolic function was assessed with the LA emptying volume = Maximum LA volume (LAVmax ) - Minimum LA volume (LAVmin ), LA emptying fraction = [(LAVmax - LAVmin )/LAVmax ] × 100, and LA ejection force calculated with Manning's method [LA ejection force = (0.5 × ρ × mitral valve area × A2 )], where ρ is the blood density and A is the late-diastolic mitral inflow velocity. Recurrent AF was detected in 35/106 (33%) during 14.6 ± 9.1 months. Univariate analysis revealed reduced LA ejection force, decreased LA emptying fraction, larger LA diameter, and elevated brain natriuretic peptide as significant variables. On multivariate analysis, reduced LA ejection force and larger LA diameter were independently associated with recurrent AF. Moreover, patients with reduced LA ejection force and larger LA diameter had a higher risk of recurrent AF than preserved LA ejection force (log-rank P = 0.0004).

CONCLUSIONS

Reduced LA ejection force and larger LA diameter were associated with poor outcome after CA for paroxysmal AF, and could be a new index to predict recurrent AF.

Для цитирования: Kishima Hideyuki, Mine Takanao, Takahashi Satoshi, Ashida Kenki, Ishihara Masaharu, Masuyama Tohru. Left atrial ejection force predicts the outcome after catheter ablation for paroxysmal atrial fibrillation.. Journal of cardiovascular electrophysiology. 2017. DOI: 10.1111/jce.13387.

Предметные рубрики MeSH