MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13157

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2017

Cryoballoon ablation in Chinese patients with paroxysmal atrial fibrillation: 1-year follow-up.

Ling Tian-You, Jin Qi, Pan Wen-Qi, Zhang Ning, Lin Chang-Jian, Lee Hon-Chi, Wu Li-Qun

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We assessed the effectiveness and safety of cryoballoon ablation (CBA) in the Chinese population with paroxysmal atrial fibrillation (AF) with a 1-year follow-up and determined the association of early recurrence of atrial tachyarrhythmias (ERAT) with late recurrence (LR).

METHODS

A total of 114 patients (age 61 ± 10 years, 78 males) with paroxysmal AF who underwent CBA were consecutively enrolled. After procedures, patients were observed for 3 days with continuous electrocardiogram monitoring in the hospital with routine follow-up visits at 3 months, 6 months, and 1 year. Documented atrial tachyarrhythmia >30 seconds was defined as recurrence. ERAT was defined as any recurrence during the first 3 months, and LR was recurrence between 3 and 12 months.

RESULTS

With the first 3 months as blanking period, 76% of patients were free of LR at 12 months. Five patients (4%) experienced complications, including phrenic nerve palsy, stroke, and groin complications. Forty-five percent of patients had ERAT in the first 3 months and 31% of patients had ERAT in the first 3 days. Patients with ERAT had higher LR rate (LRR) than those without ERAT (43% vs 8%, P < 0.001). The LRR of patients with ERAT only in the first 3 days was lower than those with ERAT both in the first 3 days and in 4-90 days (29% vs 64%, P = 0.036).

CONCLUSIONS

CBA was an effective and safe treatment option for paroxysmal AF. Patients with ERAT had higher LRR after CBA of AF. The time when ERAT occurred had an impact on LRR.

Для цитирования: Ling Tian-You, Jin Qi, Pan Wen-Qi, Zhang Ning, Lin Chang-Jian, Lee Hon-Chi, Wu Li-Qun. Cryoballoon ablation in Chinese patients with paroxysmal atrial fibrillation: 1-year follow-up.. Pacing and clinical electrophysiology : PACE. 2017. DOI: 10.1111/pace.13157.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.