MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1053-2498(01)00410-7

Медицинская библиотека · The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2002

Assessment of synchrony relationships between the native left ventricle and the HeartMate left ventricular assist device.

Maybaum Simon, Williams Mathew, Barbone Alessandro, Levin Howard, Oz Mehmet, Mancini Donna

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

It has been suggested that the cardiac cycle becomes synchronized with the LVAD. Synchronization between the left ventricle and the LVAD may be important for ventricular unloading and coronary flow. In this study, we assessed the synchrony between the cardiac and LVAD cycles.

METHODS

We studied 24 patients with HeartMate LVAD support. Native heart rate from an electrocardiogram and LVAD rate were measured at rest and peak exercise. Three patients underwent simultaneous invasive pressure measurement from the left ventricle and the aorta, and 3 patients underwent simultaneous recording of electrocardiogram and LVAD electrical signal.

RESULTS

Resting heart rate was significantly higher than LVAD rate (96 +/- 17 vs 66 +/- 15 beats [b]/min, p < 0.0001), with no correlation between the 2 (r = 0.25). Peak heart rate was significantly higher than LVAD rate (142 +/- 16 vs 102 +/- 14 b/min, p < 0.0001), with no correlation observed (r = 0.31). Electrical signal recording confirmed the absence of cardiac-LVAD synchrony. Pressure measurements revealed a cyclical intraventricular pressure variation, determined by the relationship between the cardiac and LVAD cycles. Intraventricular pressure was lowest when left ventricular systole occurred during pump filling and highest when left ventricular systole occurred during pump ejection.

CONCLUSIONS

The cardiac and LVAD cycles are not in synchrony at rest or at peak exercise. However, a cyclical variation in left ventricular pressure exists, dependent upon the phasic relationship of the cardiac-LVAD cycles, which significantly effects ventricular loading. Better understanding of this relationship may be important in developing assist devices for optimal left ventricular unloading and improvement of myocardial recovery.

Для цитирования: Maybaum Simon, Williams Mathew, Barbone Alessandro, Levin Howard, Oz Mehmet, Mancini Donna. Assessment of synchrony relationships between the native left ventricle and the HeartMate left ventricular assist device.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2002. DOI: 10.1016/s1053-2498(01)00410-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.