MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-8703(00)90318-1

Медицинская библиотека · American heart journal · 2000

Prevalence and characteristics of escape rhythms after radiofrequency ablation of the atrioventricular junction: results from the registry for AV junction ablation and pacing in atrial fibrillation. Ablate and Pace Trial Investigators.

Curtis A B, Kutalek S P, Prior M, Newhouse T T

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiofrequency ablation of the atrioventricular junction is a well-established procedure for the management of atrial fibrillation refractory to medical therapy. However, there are few data available on the prevalence and characteristics of the escape rhythms that are present after the procedure.

METHODS

The Ablate and Pace Trial was a prospective, multicenter registry of atrioventricular junction ablation and pacing in atrial fibrillation. Ablation of the atrioventricular junction was accomplished with radiofrequency energy with standard techniques. Before discharge from the hospital, patients underwent a systematic analysis of the rate and morphologic features of the escape rhythm, if any, that was present when the pacing rate was gradually decreased.

RESULTS

There were 156 patients from 16 centers who underwent attempted radiofrequency ablation of the atrioventricular junction. The procedure was successful in 155 (99%) of 156 patients. An escape rhythm was present in 104 patients (67%) after radiofrequency ablation. The escape rate ranged from 11 to 65 beats/min (mean 39 +/- 10 beats/min). Only 49 patients (31%) had an escape rate >/=40 beats/min. Of the 104 patients with an escape rhythm, 53 patients (51%) had a QRS that was unchanged from baseline. There was no correlation between the number of radiofrequency applications and the presence of an escape rhythm.

CONCLUSION

The majority of patients who undergo radiofrequency catheter ablation of the atrioventricular junction are pacemaker dependent after the procedure, as defined by lack of an escape rhythm or the presence of an escape rhythm that is <40 beats/min.

Для цитирования: Curtis A B, Kutalek S P, Prior M, Newhouse T T. Prevalence and characteristics of escape rhythms after radiofrequency ablation of the atrioventricular junction: results from the registry for AV junction ablation and pacing in atrial fibrillation. Ablate and Pace Trial Investigators.. American heart journal. 2000. DOI: 10.1016/s0002-8703(00)90318-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.