MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/arm90040039

Медицинская библиотека · Advances in respiratory medicine · 2022

Diagnostic Accuracy of Multiple D-Dimer Cutoff Thresholds and Other Clinically Applicable Biomarkers for the Detection and Radiographic Evaluation of Pulmonary Embolism.

Chrysikos Serafeim, Papaioannou Ourania, Karampitsakos Theodoros, Tavernaraki Kyriaki, Thanou Ioanna, Filippousis Petros, Anyfanti Maria, Hillas Georgios, Tzouvelekis Argyrios, Thanos Loukas, Dimakou Katerina

СтатьяПеревод пока не подготовлен

Аннотация

Background

Diagnostic work-up of pulmonary embolism (PE) remains a challenge.

Methods

We retrospectively studied all patients referred for computed tomography pulmonary angiography (CTPA) with suspicion of PE during a 12-month period (2018). The diagnostic accuracy of different D-dimer (Dd) cutoff thresholds for ruling out PE was evaluated. Furthermore, the association of Dd and red cell distribution width (RDW) with embolus location, CTPA findings, and patient outcome was recorded.

Results

One thousand seventeen (n = 1017) patients were finally analyzed (mean age: 64.6 years (SD = 11.8), males: 549 (54%)). PE incidence was 18.7%. Central and bilateral embolism was present in 44.7% and 59.5%, respectively. Sensitivity and specificity for conventional and age-adjusted Dd cutoff was 98.2%, 7.9%, and 98.2%, 13.1%, respectively. A cutoff threshold (2.1 mg/L) with the best (64.4%) specificity was identified based on Receiver Operating Characteristics analysis. Moreover, a novel proposed Dd cutoff (0.74 mg/L) emerged with increased specificity (20.5%) and equal sensitivity (97%) compared to 0.5 mg/L, characterized by concurrent reduction (17.2%) in the number of performed CTPAs. Consolidation/atelectasis and unilateral pleural effusion were significantly associated with PE (p < 0.05, respectively). Patients with consolidation/atelectasis or intrapulmonary nodule(s)/mass on CTPA exhibited significantly greater median Dd values compared to patients without the aforementioned findings (2.34, (IQR 1.29−4.22) vs. 1.59, (IQR 0.81−2.96), and 2.39, (IQR 1.45−4.45) vs. 1.66, (IQR 0.84−3.12), p < 0.001, respectively). RDW was significantly greater in patients who died during hospitalization (p = 0.012).

Conclusions

Age-adjusted Dd increased diagnostic accuracy of Dd testing without significantly decreasing the need for imaging. The proposed Dd value (0.74 mg/L) showed promise towards reducing considerably the need of CTPA. Multiple radiographic findings have been associated with increased Dd values in our study.

Для цитирования: Chrysikos Serafeim, Papaioannou Ourania, Karampitsakos Theodoros, Tavernaraki Kyriaki, Thanou Ioanna, Filippousis Petros, Anyfanti Maria, Hillas Georgios, Tzouvelekis Argyrios, Thanos Loukas, Dimakou Katerina. Diagnostic Accuracy of Multiple D-Dimer Cutoff Thresholds and Other Clinically Applicable Biomarkers for the Detection and Radiographic Evaluation of Pulmonary Embolism.. Advances in respiratory medicine. 2022. DOI: 10.3390/arm90040039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.