DOI 10.1371/journal.pone.0268483
Xpert MTB/RIF Ultra versus Xpert MTB/RIF for diagnosis of tuberculous pleural effusion: A systematic review and comparative meta-analysis.
Аннотация
OBJECTIVE
We compared diagnostic accuracy of pleural fluid Xpert MTB/RIF (Xpert) and Xpert MTB/RIF Ultra (Ultra) assays for diagnosing tuberculous pleural effusion (TPE), through systematic review and comparative meta-analysis.
METHODS
We searched PubMed and Embase databases for publications reporting diagnostic accuracy of Xpert or Ultra for TPE. We used bivariate random-effects modeling to summarize diagnostic accuracy information from individual studies using either mycobacterial culture or composite criteria as reference standard. We performed meta-regression through hierarchical summary receiver operating characteristic (HSROC) modeling to evaluate comparative performance of the two tests from studies reporting diagnostic accuracy of both in the same study population.
RESULTS
We retrieved 1097 publications, and included 74 for review. Summary estimates for sensitivity and specificity for Xpert were 0.52 (95% CI 0.43-0.60, I2 82.1%) and 0.99 (95% CI 0.97-0.99, I2 85.1%), respectively, using culture-based reference standard; and 0.21 (95% CI 0.17-0.26, I2 81.5%) and 1.00 (95% CI 0.99-1.00, I2 37.6%), respectively, using composite reference standard. Summary estimates for sensitivity and specificity for Ultra were 0.68 (95% CI 0.55-0.79, I2 80.0%) and 0.97 (95% CI 0.97-0.99, I2 92.1%), respectively, using culture-based reference standard; and 0.47 (95% CI 0.40-0.55, I2 64.1%) and 0.98 (95% CI 0.95-0.99, I2 54.8%), respectively, using composite reference standard. HSROC meta-regression yielded relative diagnostic odds ratio of 1.28 (95% CI 0.65-2.50) and 1.80 (95% CI 0.41-7.84) respectively in favor of Ultra, using culture and composite criteria as reference standard.
CONCLUSION
Ultra provides superior diagnostic accuracy over Xpert for diagnosing TPE, mainly because of its higher sensitivity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.